SlideShare ist ein Scribd-Unternehmen logo
1 von 65
1
LIQUID CHROMATOGRAPHY-
MASS SPECTROMETRY (LC-
MS)
Presented by
S.NAVEEN JAIN
11AB1R0078
UNDER THE ESTEEMED
GUIDANCE OF
Mr. Ch. DEVADASU M.Pharm
Assistant professor
Department of PA & QA
VIGNAN PHARMACY COLLEGE
(Approved by AICTE, PCI &
Affiliated to JNTU-K)
VADLAMUDI, 522213.
HISTORY
INTRODUCTION
THEORY
MASS SPECTRUM
LC-MS
ION INTERFACE SOURCES
IONIZATION SOURCES
MASS ANALYZERS
DETECTORS
APPLICATIONS
CONCLUSION
REFERENCESVIGNAN PHARMACY COLLEGE 2
A Brief History of Mass Spectrometry
In 1897, Modern mass spectrometry (MS) is credited to the cathode-
ray-tube experiments of J.J. Thomson of Manchester, England.
In 1953, Wolfgang Paul’s invention of the quadrupole and
quadrupole ion trap earned him the Nobel Prize in physics.
In 1968, Malcolm Dole developed electrospray ionization (ESI).
In 1974, Atmospheric pressure chemical ionization (APCI) was
developed by Horning.
In 1983, Vestal and Blakely’s work with heating a liquid stream
known as thermospray was developed.
VIGNAN PHARMACY COLLEGE 3
The concept of mass spectrometry was first put forth by
Sir J.J Thomson, English Physicist Who discovered the
electron in 1887.
He got 1906 Nobel Laureate in Physics.
DEMPSTER
Sir J.J Thomson
4VIGNAN PHARMACY COLLEGE
VIGNAN PHARMACY COLLEGE 5
What does a mass spectrometer do?
Mass –spec or simply MS is a super important technique
Mass spec is easy technique to give you Molecular weight
(from molecular ion (M+)
You can get Molecular formula (Elements present).
Nearly ALL ELEMENTS in the periodic table can be determined by
mass spectrometry.
MS is incredibly valuable in getting structure (from fragments) of
Bio molecules such as peptides and proteins and also
natural products and also organic structures.
It can give information about chemical structures.
6VIGNAN PHARMACY COLLEGE
VIGNAN PHARMACY COLLEGE 7
Inlet
Ion
Source
Mass
Filter
Detector
Data
System
High Vacuum System
Sample Plate
Target
HPLC
GC
Solids probe
MALDI
ESI
Ion Spray
FAB
LSIMS
EI/CI
TOF
Quadrupole
Ion Trap
Mag. Sector
FTMS
Electron
Multiplier,
Faraday cup
PC’s
UNIX
Mac
Basic components in mass spectrometer
Mass Sor
Illustration of the basic components of a mass spectrometry system.
Solid
• Liquid
• Vapor
Ionization
Source
Mass
Analyzer Detector
Inlet
Form ions
charged molecules
selected
ions
Data
System
Sort or separates
ions by M/Z
When ions strike
Detector it Detect ions
The inlet transfers the sample into the vacuum of the mass spectrometer. In the
source region, neutral sample molecules are ionized and then accelerated into
the mass analyzer. The mass analyzer is the heart of the mass spectrometer.
This section separates ions, either in space or in time, according to their mass to
charge ratio. After the ions are separated, they are detected and the signal is
transferred to a data system for analysis..
Neutral sample
molecules
9VIGNAN PHARMACY COLLEGE
VIGNAN PHARMACY COLLEGE 10
VIGNAN PHARMACY COLLEGE 11
The mass spectrometer is an instrument which help in separating the individual
atoms or molecules because of difference in their masses.
Consider a molecule M, Which is bombarded with a beam of electrons
M + e- M+. +2e-
where, M+. is molecular ion or radical ion
2e- is electron
Now voltage “v” is applied in an electric field then ions are accelerated. In this
condition the energy given to each particle is zV and this is equal to kinetic
energy which is equal to 1/2mv2 .
THEORY
i.e. potential energy=kinetic energy
zV = 1/2mv2
2zV = mv2
2zV/m= v2
= v
Where V = Velocity of particle
m = mass
z = charge of an electron
V = Acceleration voltage
All the particles posses some energy zV with some kinetic energy
1/2mv2, but m value changes from molecule to molecule with respect velocity
‘v’ also changes. i.e. ½ mv=zV
VIGNAN PHARMACY COLLEGE 12
When all charged particles have been accelerated by an applied voltage, they
enter into a magnetic field “H”. Then attractive force is HzV. And balancing
force of particle is mv2 /r.
Centripetal = Centrifugal
HzV=mv2/r
Hz=mv/r
From the above equation v=
Hz=m / r
By squaring on both sides
H2 z2 = m2 (2zV/m) / r2
H2 z = 2v m/ r2
m/z = H2 r2 / 2v
VIGNAN PHARMACY COLLEGE 13
MASS SPECTRUM
The mass spectrum is the plot of mass to charge ratio of positively charged
ions against their relative abundance. The m/z ratio are taken along the
abscissa, while relative abundance is taken on ordinate.
BASE PEAK:
The most intense peak in the mass spectrum is called the base peak. Base
peak is the highest peak it is assigned a relative intensity of 100%.
VIGNAN PHARMACY COLLEGE 14
MOLECULAR ION PEAK:
The ion formed from a molecule by removal of one electron of lowest
ionization potential is known as molecular ion.
The molecular ion is detected as mass to charge ratio that corresponds to
molecular weight of molecule. The molecular ion peak gives the molecular
weight of compound . The molecular ion peak is highest mass number except
isotope peak. Molecular ion peakBase peak
Fragment ions
VIGNAN PHARMACY COLLEGE 15
FRAGMENT IONS:
The ions produced from the molecular ion by cleavage of bonds are called
fragment ions
They have lower masses and used as building blocks to reconstruct the
molecular structure. Fragmentation of molecular ion cleavage bond occurs in
heterolytic and homolytic cleavage.
METASTABLE IONS:
Mass spectrum of molecule shows sharp peaks at m/z integrals. But some show
diffuse, broad low intensity peaks at non integral m/z values these are called
metastable ions
m1
+ m2
++ neutral fragment
VIGNAN PHARMACY COLLEGE 16
If in the reaction m1
+--------->m2
++ takes place in source then the
daughter ion may be m2
+. But m1
+----->m2
++ if occurs after the source
and before arrival at collector at lower mass than m2+ and is said to be
metastable ion m*.The peak (m*) due to such fragmentation therefore
occurs at lower mass than m2+ and generally broad. The relation between
the m* with that of m1
+ & m2+ can be written as
m*=(mz+)/m1
VIGNAN PHARMACY COLLEGE 17
Relativeabundance
m/z values
110108
81
79
29 –C2 H5
M+2M+
CH3CH2Br
VIGNAN PHARMACY COLLEGE 18
Liquid chromatography–mass spectrometry (LC-MS, or alternatively
HPLC-MS) is an ADVANCED ANALYTICAL INSTRUMNTAL
technique that combines the physical separation capabilities of LIQUID
CHROMATOGRAPHY (or HPLC) with the mass analysis capabilities
of MASS SPECTROMETER
VIGNAN PHARMACY COLLEGE 19
It is the combination of liquid
chromatography and the
mass spectrometry.
In LC-MS we are removing the
detector from the column of
LC and fitting the column to
interface of MS.
In the most of the cases the
interface used in LC-MS are
ionization source.
20VIGNAN PHARMACY COLLEGE
 HPLC is a method for separating a complex mixture in to its individual
components.
 High sensitivity of mass spectrometry provides the information for
identification of compounds or structural elucidation of compounds.
 Combination of these two techniques is LC-MS
VIGNAN PHARMACY COLLEGE 21
VIGNAN PHARMACY COLLEGE 22
ION
INTERFACE
SOURCES
DIRECT
CHEMICAL
IONIZATION
MOVING WIRE
OR BELT
INTERFACE
THERMOSPRAY
DIRECT CHEMICAL IONIZATION:
The simplest way to introduce HPLC effluent into mass spectrometer is to
split the flow.
Chemical ionization is most suitable in this technique because under CI
pressure conditions, solvent rates as high as 10 micro lit / min can be
tolerated. This permits10-20 micro lit/ min (1-2%) eluate from the HPLC to
that of the ion source.
VIGNAN PHARMACY COLLEGE 23
VIGNAN PHARMACY COLLEGE 24
MOVING WIRE OR BELT INTERFACE:
The moving wire or belt interface consists of an auxiliary vacuum
chamber through which a continuous train carries the column eluate,
evaporates the solvent and subsequently vaporizes the solute. The
moving interface was developed by Mc Fadden et al84,85 which can
transfer upto 30-40% of solute from HPLC to ion source. The residual
solvent helps to maintain vaccum in the MS. The sample is finally
conducted into the ion source, where it vaporizes.
VIGNAN PHARMACY COLLEGE 25
VIGNAN PHARMACY COLLEGE 26
THERMOSPRAY:
The eluent from the column is vapourised and a portion of vapour is transferred
to the mass spectrometer and rest of the vapour is pumped to waste. As a result
a supersonic jet vapour, containing a mist of particles and solvent droplet is
created. There vaporization takes place in presence of an electrolyte the LC
buffer, the droplets are charged. And finally they enter into the ionization
chamber.
VIGNAN PHARMACY COLLEGE 27
VIGNAN PHARMACY COLLEGE 28
Electron spray Ionization [ESI]
Atmospheric pressure chemical ionization
[APCI]
Atmospheric Pressure photo ionization
[APPI]
The LC eluent is sprayed into chambers in presence of strong
electrostatic field and heated drying gas. Large molecules even acquires
more than one charge this process mathematically called deconvolution.
The heated gas causes solvent in the droplet evaporation. The repulsive
force b/w ions with like charge exceeds cohesive force and ions are eject
into gas phase and passed into the analyser.
VIGNAN PHARMACY COLLEGE 29
VIGNAN PHARMACY COLLEGE 30
In APCI, the LC eluent is sprayed through a heated [250-400] vapourises at
atmospheric pressure. The heat vapourises liquid which results gas solvent
are ionized by corona needle by which electrons are discharged. Thereby
chemical reactions takes place and ions passes through a capillary orifice
into mass analyser.
VIGNAN PHARMACY COLLEGE 31
Atmospheric pressure photo ionization is relatively never technique. Here a
discharge UV lamp is placed which generates photons in a narrow range of
ionization energies. It shows its ionization for highly non polar compounds
and low flow rates[<100m/min]
VIGNAN PHARMACY COLLEGE 32
Mass analyzers
Quadrupole Ion trap Time of
flight
Fourier transform
ion cyclotron
resonance
VIGNAN PHARMACY COLLEGE 33
They deflects ions down a curved tubes in a magnetic fields based on
their kinetic energy determined by the mass, charge and velocity. The
magnetic field is scanned to measure different ions.
VIGNAN PHARMACY COLLEGE 34
In a quadrupole mass analyser a set of four rods are arranged parallel to
the direction. Here a DC current and radio frequency RF is applied to
generate oscillating electrostatic field in between the rods. Based on this
only m/z is been determined and stable oscillation takes place. And ion
travels in quadrupole axis with cork screw type of trajectory.
VIGNAN PHARMACY COLLEGE 35
TOF mass analyser is based on simple idea that the
velocities of two ions are created by uniform
electromagnetic force applied to all the ions at same
time, causing them to accelerate down a flight tube.
Lighter ions travels faster and strike the detector first so
that the m/z ratio of ions is detected.
VIGNAN PHARMACY COLLEGE 36
The ion trap mass analyser operates by similar principles where it
consists of circular ring electrode
Plus two end caps that form a chamber. Here AC or DC power along RF
potential is applied between the cups and the ring electrode.
There the ions entering into the chamber are trapped by electromagnetic
fields and they oscillates in concentric trajectories. This process is
called resonant ejection.
VIGNAN PHARMACY COLLEGE 37
VIGNAN PHARMACY COLLEGE 38
VIGNAN PHARMACY COLLEGE 39
In this ions entering are trapped in circular well defined orbits for extended
periods by electrical and magnetic fields. These are excited by radio
frequency RF and generates the current. This current is converted to
Fourier transform into orbital frequencies. The angular frequency of
motion is called cyclotron frequency.
DETECTORS
Photo
graphic
plates
Faraday
cup
Electron
multiplier
Channel
electron
multipliers
Scintillation
detectors
VIGNAN PHARMACY COLLEGE 40
Photo graphic plates:
It is used as it is capable of higher resolution and speeder than
electronic devices. i.e. it can detect ions of all the masses and provide
a reverse geometry analyzer.
VIGNAN PHARMACY COLLEGE 41
Faraday Cup:
It is a metal cup into which all the ions are directed and the signal
produced is very stable and reproducible. It is used on spectrometers
where quantitative data is very important
VIGNAN PHARMACY COLLEGE 42
Electron multipliers:
In this the current can be measured so accurately by just one ion strikes the
detector can be measured i.e. when an ion strikes the surface of electron
multiplier two electron are ejected. This process continues until the end of
electro multiplier end is reached and electric current is analyzed and recorded
with electron multiplier surface. Equation describe is 2n
Where n= no of collisions with electron multiplier surface.
VIGNAN PHARMACY COLLEGE 43
DATA HANDLING
All the mass spectrometers now employ computer control of same functions
and also use a computerised display and output.
The amount of data generated even by a fairly modest mass spectrometer is
very large indeed, a single run may store data for upto 100 fragments from
each type of molecule and if, LCMS analyses is being performed, a complete
mass spectrum is generated and stored every sec for upto 90 min
VIGNAN PHARMACY COLLEGE 44
APPLICATIONS
MOLECULAR WEIGHT DETERMINATION
DIFFERENTIATION OF SIMILAR OCTAPEPTIDES:
The spectra of octa peptides whose m/z ratio differ only by 1m/z. The only
difference in sequence is at C-terminus that is one having threonine and other
having threonine amide.
VIGNAN PHARMACY COLLEGE 45
DETERMINATION OF MOLECULAR WEIGHT OF GREEN
FLORESCENT PROTEIN:
GRF is 27000 Dalton protein with 238 amino acids. During electron spray
ionization GFP acquires multiple charges. This allows to be analyzed by mass
spectrometer by m/z range. Here the mass deconvolution is then used to
determine the weight of the protein GFP.
VIGNAN PHARMACY COLLEGE 46
STRUCTURAL DETERMINATION:
LC/MS is also applied for the information about the molecular structure. this
can be in addition of mol wt if the identity of the compound is already known.
STRUCUTRAL DETERMINATION OF GINSENOSIDES USING
LC/MS ANALYSIS:
GINSENG root have dozens of biologically active saponins called
gensinosides. In mass spectrometer, ion trap mass analyser permits multiplier
stages of precursor ion isolation and fragmentation
The most prominent feature is sodium adduct ion corresponding to cleavage of
single bonded glycoside.
Subsequent isolation and fragmentation at m/z 789.7 yields two products.
VIGNAN PHARMACY COLLEGE 47
1.A more abundant ion at m/z 365.1 losses oligosaccharide ion
2. Loss of less abundant ion at m/z 627.5 i.e. de-oxyhexose sugar
VIGNAN PHARMACY COLLEGE 48
PHARMACEUTICAL APPLICATIONS
RAPID CHROMATOGRAPH OF BENZODIAZEPINES:
It allows compounds to be separated even they are chromatographically
unresolved. A series of benzodiazepines are analyzed using both UV and MS
detectors. In this chlorine cl- has a characteristic abundance of 2 most abundant
isotopes. By which TRAIZOLAM spectrum shows a two cl- ions and
DIAZEPAM shows only one cl- ion.
VIGNAN PHARMACY COLLEGE 49
IDENTIFICATION OF BILE ACID METABOLITES:
The use of in-vitro incubation of bile acid deoxycholic with rat liver
microsomes to stimulate metabolism of drug candidate. These precursor ions
are were automatically fragmented and full scan ion spectra is collected.
The first graph shows the base peak chromatogram.
The second shows minor metabolite which is eluted at 9.41min.
Third graph show product spectrum from the ion at m/z 407 which confirms
identity.
VIGNAN PHARMACY COLLEGE 50
Graph-1
Graph-2
Graph-3
VIGNAN PHARMACY COLLEGE 51
CLINICAL APPLICATIONS
HIGH SENSITIVITY DETECTION OF TRIMIPRAMINE AND
THIORIDAZINE:
Triminpramine is a tricyclic anti depressant, Thioridazine is a tranquilizer
when these compounds are detected by UV there is no extract level. For this
single quadrupole of LCMS was been used for analysis by ion monitoring.
VIGNAN PHARMACY COLLEGE 52
GENERAL CONSIDERATION:
Immunoassays can be detected as it is more sensitive and very easily allocated.
Similarly many drug and other small molecules assay are readily performed by
immunoassay, LC/MS, GLC etc.
Lc/ms is best suited for either problems i.e. those which have tedious specimen
preparation protocols in which more than one compound must be measured
simultaneously.
BIOCHEMICAL GENETICS:
One of the seminal applications of Lc/ms was multiple analyte screening for
inborn errors of metabolism.
Few of inherited metabolic disorders detected by newborn screening with
Lc/ms.
VIGNAN PHARMACY COLLEGE 53
 AMINO ACIDOPATHIES
Phenyl ketoxuria
Tyrosinemia
Non ketotic hyperglycemia
Argininemia
 ORGANIC ACIDEMIAS
Glutaric academia type I
Propionic academia
Methyl malonic academia
 DEFECTS OF FATTY ACID OXIDATION
Short chain acyl-CoA dehydrogenase deficiency
Ethylmalonic academia
Carnitine transport defect
VIGNAN PHARMACY COLLEGE 54
THERAPEUTIC DRUG MONITORING:
A direct injection of HPLC/MS method has been developed for the rapid
identification and quantitation of seven tricyclic antidepressants in human
plasma can be done.
A sensitive and specific method is determined for phenprocoumon, warfarin in
human plasma by Lc/ms has been developed for monitoring of anticoagulant
therapy.
VIGNAN PHARMACY COLLEGE 55
FOOD APPLICATIONS
INDENTIFICATION OF ALFATOXINS IN FOOD:
Aflatoxins are fungi produced in food. By total in chromatogram we can detect
4 different aflatoxins. Even though they are structurally very similar to each
other but can be uniquely identified by LC/ms.
VIGNAN PHARMACY COLLEGE 56
VIGNAN PHARMACY COLLEGE 57
PHARMACOLOGY:
Since most drugs have a core chemical structure, which is retained by
their metabolites, the determination of drug metabolites in pharmacology
is now dominated by Lc/ms. The core structure produces charged or
neutral fragment. The charged can be detected using ion scanning
strategy. Unchanged can be recognized by neutral loss scanning.
VIGNAN PHARMACY COLLEGE 58
TOXICOLOGY
•An even simpler strategy solid phase extraction and direct flow
injection with no HPLC has been shown to be viable using clinical
specimens.
• Determination of designer drugs 3,4-methylene
dioxymethamphetamine[MDMA], 3,4-methylenedioxyethyl
amphetamine[MDEA] and 3,4-methylenedioxy
amphetamine[MDA] by Lc/ms has been showing using fluorescent
detection.
•The method was found suitable for determination for whole blood,
serum, vitreous humor and urine.
VIGNAN PHARMACY COLLEGE 59
IN DRUG DISCOVERY
Drug discovery involves a number of phases, including target
identification, lead identification, small molecule optimization and pre-
clinical and clinical development.
Target identification has been speeded up as result of genomics but the
measurement of gene transcription through detection of RNA does not
necessarily indicate proteins produced are, which are translated by
glycosylation or phosphorycation.
With advances in Lc/ms, identification of translated proteins is
possible.
VIGNAN PHARMACY COLLEGE 60
 LC-MS has proved to be an extremely sensitive and specific
technique for the analysis of pharmaceuticals.
 It plays important role in the studies of drug metabolism,
discovery of new drug candidates and the analysis,
identification and characterisation of impurities and
degradants in drug substances and products.
VIGNAN PHARMACY COLLEGE 61
VIGNAN PHARMACY COLLEGE 62
Pharmaceutical Analysis -A Text book for pharmacy students &
chemical applications By- DAVID G. WATSON.
Page no: 206-213.
Instrumental analysis By- SKOOG, HOLLER,CROUCH.
Page no- 607-631.
Spectroscopy By- PAVIA, LAMPMAN,KRIZ, VYVYAM
Page no- 401-417.
Elementary Organic Spectroscopy principles &
chemical applications. By- Y.R.SHARMA
Page No- 280-289
Instrumental Methods Of Chemical Analysis. By- B.K
SHARMA
Page No- C286-C291
Instrumental Methods Of Chemical Analysis By-
GURDEEP R.CHATWAL,SHAM K.ANAND
Page No 2.272-2.286
VIGNAN PHARMACY COLLEGE 63
VIGNAN PHARMACY COLLEGE 64
Organic Spectroscopy Principles & Applications. By-
JAG MOHAN
Page no 443-446
Vogel’s Text Book Of Quantitative Chemical Analysis.
By- J.MENDHAN, R C DENNY, J.D. BARNES, M.THOMAS,
B. SIVA SANKAR.
Page no 720-741
AGILENT TECHNOLOGIES.
Page no 6-30
VIGNAN PHARMACY COLLEGE 66

Weitere ähnliche Inhalte

Was ist angesagt?

Was ist angesagt? (20)

Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
Hyphenated techniques(GC-MS/MS, LC-MS/MS,  HPTLC-MS)Hyphenated techniques(GC-MS/MS, LC-MS/MS,  HPTLC-MS)
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
 
Lc ms
Lc msLc ms
Lc ms
 
LC-MS
LC-MSLC-MS
LC-MS
 
Mass spectrometry
Mass spectrometryMass spectrometry
Mass spectrometry
 
Fragmentation techniques
Fragmentation techniquesFragmentation techniques
Fragmentation techniques
 
Instrumentation and application of LC-MS/MS in bioanalysis
Instrumentation and application of LC-MS/MS in bioanalysisInstrumentation and application of LC-MS/MS in bioanalysis
Instrumentation and application of LC-MS/MS in bioanalysis
 
Mass spectrometry
Mass spectrometryMass spectrometry
Mass spectrometry
 
Quadrupole and Time of Flight Mass analysers.
 Quadrupole and Time of Flight Mass analysers. Quadrupole and Time of Flight Mass analysers.
Quadrupole and Time of Flight Mass analysers.
 
Mass spectrometry final.pptx
Mass spectrometry final.pptxMass spectrometry final.pptx
Mass spectrometry final.pptx
 
Ionizaion Techniques - Mass Spectroscopy
Ionizaion Techniques - Mass SpectroscopyIonizaion Techniques - Mass Spectroscopy
Ionizaion Techniques - Mass Spectroscopy
 
Quadrupole mass spectrometer
Quadrupole mass spectrometerQuadrupole mass spectrometer
Quadrupole mass spectrometer
 
Chemical ionization
Chemical ionizationChemical ionization
Chemical ionization
 
MASS SPECTROSCOPY & ITS INSTRUMENTATION
MASS SPECTROSCOPY & ITS INSTRUMENTATIONMASS SPECTROSCOPY & ITS INSTRUMENTATION
MASS SPECTROSCOPY & ITS INSTRUMENTATION
 
Mass spectroscopy
Mass spectroscopyMass spectroscopy
Mass spectroscopy
 
Mass spectrometry basic principle & Instrumentation
Mass spectrometry basic principle & InstrumentationMass spectrometry basic principle & Instrumentation
Mass spectrometry basic principle & Instrumentation
 
SlideShare Presentation on Mass spectrophotometer
SlideShare Presentation on Mass spectrophotometerSlideShare Presentation on Mass spectrophotometer
SlideShare Presentation on Mass spectrophotometer
 
Mass spectrometry
Mass spectrometryMass spectrometry
Mass spectrometry
 
Atmospheric Pressure Chemical Ionization
Atmospheric Pressure Chemical IonizationAtmospheric Pressure Chemical Ionization
Atmospheric Pressure Chemical Ionization
 
MASS SPECTROMETRY=.pdf
MASS SPECTROMETRY=.pdfMASS SPECTROMETRY=.pdf
MASS SPECTROMETRY=.pdf
 
Mass Analyser
Mass AnalyserMass Analyser
Mass Analyser
 

Andere mochten auch (7)

Comparative genomics and proteomics
Comparative genomics and proteomicsComparative genomics and proteomics
Comparative genomics and proteomics
 
Protein protein interactions
Protein protein interactionsProtein protein interactions
Protein protein interactions
 
Maldi tof
Maldi tofMaldi tof
Maldi tof
 
MALDI - TOF
MALDI - TOFMALDI - TOF
MALDI - TOF
 
Protein protein interactions
Protein protein interactionsProtein protein interactions
Protein protein interactions
 
MALDI
MALDIMALDI
MALDI
 
Sds-Page
Sds-Page Sds-Page
Sds-Page
 

Ähnlich wie LC-MS INSTURMENTATION & APPLICATIONS

Ähnlich wie LC-MS INSTURMENTATION & APPLICATIONS (20)

Mass spectrometry
Mass spectrometryMass spectrometry
Mass spectrometry
 
GCMS
GCMSGCMS
GCMS
 
Prabhakar singh ii sem-paper v-mass spectroscopy
Prabhakar singh  ii sem-paper v-mass spectroscopyPrabhakar singh  ii sem-paper v-mass spectroscopy
Prabhakar singh ii sem-paper v-mass spectroscopy
 
Mass spectroscopy
Mass spectroscopyMass spectroscopy
Mass spectroscopy
 
Mass spectrometer
Mass spectrometerMass spectrometer
Mass spectrometer
 
Mass spectrometer
Mass spectrometerMass spectrometer
Mass spectrometer
 
mass spectrometery
mass spectrometerymass spectrometery
mass spectrometery
 
Mass Spectrometry
Mass SpectrometryMass Spectrometry
Mass Spectrometry
 
LC- MS
LC- MS LC- MS
LC- MS
 
Mass spectroscopy
Mass spectroscopyMass spectroscopy
Mass spectroscopy
 
Instrumentation of Mass Spectrometry
 Instrumentation of Mass Spectrometry Instrumentation of Mass Spectrometry
Instrumentation of Mass Spectrometry
 
Mass spectroscopy & it's instrumentations
Mass spectroscopy & it's instrumentationsMass spectroscopy & it's instrumentations
Mass spectroscopy & it's instrumentations
 
LC-MS, NMR, FTIR.pptx
LC-MS, NMR, FTIR.pptxLC-MS, NMR, FTIR.pptx
LC-MS, NMR, FTIR.pptx
 
Mass principle FOR PG PHARMACEUTICAL ANALYSIS
Mass principle FOR PG PHARMACEUTICAL ANALYSISMass principle FOR PG PHARMACEUTICAL ANALYSIS
Mass principle FOR PG PHARMACEUTICAL ANALYSIS
 
Mass spectrometry
Mass spectrometry Mass spectrometry
Mass spectrometry
 
Mass spectroscopy by dr. pramod r. padole
Mass spectroscopy by dr. pramod r. padoleMass spectroscopy by dr. pramod r. padole
Mass spectroscopy by dr. pramod r. padole
 
Mass spectrometry principle working inttumentation advantages diadvantages GC...
Mass spectrometry principle working inttumentation advantages diadvantages GC...Mass spectrometry principle working inttumentation advantages diadvantages GC...
Mass spectrometry principle working inttumentation advantages diadvantages GC...
 
Mass spectroscopy -> by Mohit kumar
Mass spectroscopy -> by Mohit kumarMass spectroscopy -> by Mohit kumar
Mass spectroscopy -> by Mohit kumar
 
mass spectrometery
mass spectrometerymass spectrometery
mass spectrometery
 
mass spectroscopy presentation.pptx
mass spectroscopy presentation.pptxmass spectroscopy presentation.pptx
mass spectroscopy presentation.pptx
 

Mehr von Raju Sanghvi

Mehr von Raju Sanghvi (11)

Rheology
RheologyRheology
Rheology
 
kinetics and drug stability
kinetics and drug stability kinetics and drug stability
kinetics and drug stability
 
Drug distribution in hospital pharmacy
Drug distribution in hospital pharmacyDrug distribution in hospital pharmacy
Drug distribution in hospital pharmacy
 
Colum chromatography
Colum chromatographyColum chromatography
Colum chromatography
 
Tablets
TabletsTablets
Tablets
 
Antihistamines
AntihistaminesAntihistamines
Antihistamines
 
Receptors
ReceptorsReceptors
Receptors
 
ATOMIC ABSORPTION SPECTROPHOTOMETRY
ATOMIC ABSORPTION SPECTROPHOTOMETRYATOMIC ABSORPTION SPECTROPHOTOMETRY
ATOMIC ABSORPTION SPECTROPHOTOMETRY
 
ANTI - INFLAMMATORY ACTIVITY OF LEAVES OF JATROPHA GOSSYPIFOLIA L.
ANTI - INFLAMMATORY ACTIVITY OF LEAVES OF JATROPHA GOSSYPIFOLIA  L.ANTI - INFLAMMATORY ACTIVITY OF LEAVES OF JATROPHA GOSSYPIFOLIA  L.
ANTI - INFLAMMATORY ACTIVITY OF LEAVES OF JATROPHA GOSSYPIFOLIA L.
 
COMPARISION BETWEEN 1 H & 13 C NMR
COMPARISION  BETWEEN  1 H  & 13 C NMRCOMPARISION  BETWEEN  1 H  & 13 C NMR
COMPARISION BETWEEN 1 H & 13 C NMR
 
Anti cancer drugs
Anti cancer drugsAnti cancer drugs
Anti cancer drugs
 

Kürzlich hochgeladen

Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
kauryashika82
 
1029 - Danh muc Sach Giao Khoa 10 . pdf
1029 -  Danh muc Sach Giao Khoa 10 . pdf1029 -  Danh muc Sach Giao Khoa 10 . pdf
1029 - Danh muc Sach Giao Khoa 10 . pdf
QucHHunhnh
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
ZurliaSoop
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
QucHHunhnh
 

Kürzlich hochgeladen (20)

Unit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptxUnit-IV- Pharma. Marketing Channels.pptx
Unit-IV- Pharma. Marketing Channels.pptx
 
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...Kodo Millet  PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
Kodo Millet PPT made by Ghanshyam bairwa college of Agriculture kumher bhara...
 
SOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning PresentationSOC 101 Demonstration of Learning Presentation
SOC 101 Demonstration of Learning Presentation
 
UGC NET Paper 1 Mathematical Reasoning & Aptitude.pdf
UGC NET Paper 1 Mathematical Reasoning & Aptitude.pdfUGC NET Paper 1 Mathematical Reasoning & Aptitude.pdf
UGC NET Paper 1 Mathematical Reasoning & Aptitude.pdf
 
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
 
Micro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdfMicro-Scholarship, What it is, How can it help me.pdf
Micro-Scholarship, What it is, How can it help me.pdf
 
1029 - Danh muc Sach Giao Khoa 10 . pdf
1029 -  Danh muc Sach Giao Khoa 10 . pdf1029 -  Danh muc Sach Giao Khoa 10 . pdf
1029 - Danh muc Sach Giao Khoa 10 . pdf
 
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
TỔNG ÔN TẬP THI VÀO LỚP 10 MÔN TIẾNG ANH NĂM HỌC 2023 - 2024 CÓ ĐÁP ÁN (NGỮ Â...
 
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Hongkong ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introduction
 
Introduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The BasicsIntroduction to Nonprofit Accounting: The Basics
Introduction to Nonprofit Accounting: The Basics
 
Python Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docxPython Notes for mca i year students osmania university.docx
Python Notes for mca i year students osmania university.docx
 
Third Battle of Panipat detailed notes.pptx
Third Battle of Panipat detailed notes.pptxThird Battle of Panipat detailed notes.pptx
Third Battle of Panipat detailed notes.pptx
 
Spatium Project Simulation student brief
Spatium Project Simulation student briefSpatium Project Simulation student brief
Spatium Project Simulation student brief
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
 
How to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POSHow to Manage Global Discount in Odoo 17 POS
How to Manage Global Discount in Odoo 17 POS
 
psychiatric nursing HISTORY COLLECTION .docx
psychiatric  nursing HISTORY  COLLECTION  .docxpsychiatric  nursing HISTORY  COLLECTION  .docx
psychiatric nursing HISTORY COLLECTION .docx
 
Accessible Digital Futures project (20/03/2024)
Accessible Digital Futures project (20/03/2024)Accessible Digital Futures project (20/03/2024)
Accessible Digital Futures project (20/03/2024)
 
Making communications land - Are they received and understood as intended? we...
Making communications land - Are they received and understood as intended? we...Making communications land - Are they received and understood as intended? we...
Making communications land - Are they received and understood as intended? we...
 
ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.ICT role in 21st century education and it's challenges.
ICT role in 21st century education and it's challenges.
 

LC-MS INSTURMENTATION & APPLICATIONS

  • 1. 1 LIQUID CHROMATOGRAPHY- MASS SPECTROMETRY (LC- MS) Presented by S.NAVEEN JAIN 11AB1R0078 UNDER THE ESTEEMED GUIDANCE OF Mr. Ch. DEVADASU M.Pharm Assistant professor Department of PA & QA VIGNAN PHARMACY COLLEGE (Approved by AICTE, PCI & Affiliated to JNTU-K) VADLAMUDI, 522213.
  • 2. HISTORY INTRODUCTION THEORY MASS SPECTRUM LC-MS ION INTERFACE SOURCES IONIZATION SOURCES MASS ANALYZERS DETECTORS APPLICATIONS CONCLUSION REFERENCESVIGNAN PHARMACY COLLEGE 2
  • 3. A Brief History of Mass Spectrometry In 1897, Modern mass spectrometry (MS) is credited to the cathode- ray-tube experiments of J.J. Thomson of Manchester, England. In 1953, Wolfgang Paul’s invention of the quadrupole and quadrupole ion trap earned him the Nobel Prize in physics. In 1968, Malcolm Dole developed electrospray ionization (ESI). In 1974, Atmospheric pressure chemical ionization (APCI) was developed by Horning. In 1983, Vestal and Blakely’s work with heating a liquid stream known as thermospray was developed. VIGNAN PHARMACY COLLEGE 3
  • 4. The concept of mass spectrometry was first put forth by Sir J.J Thomson, English Physicist Who discovered the electron in 1887. He got 1906 Nobel Laureate in Physics. DEMPSTER Sir J.J Thomson 4VIGNAN PHARMACY COLLEGE
  • 6. What does a mass spectrometer do? Mass –spec or simply MS is a super important technique Mass spec is easy technique to give you Molecular weight (from molecular ion (M+) You can get Molecular formula (Elements present). Nearly ALL ELEMENTS in the periodic table can be determined by mass spectrometry. MS is incredibly valuable in getting structure (from fragments) of Bio molecules such as peptides and proteins and also natural products and also organic structures. It can give information about chemical structures. 6VIGNAN PHARMACY COLLEGE
  • 8. Inlet Ion Source Mass Filter Detector Data System High Vacuum System Sample Plate Target HPLC GC Solids probe MALDI ESI Ion Spray FAB LSIMS EI/CI TOF Quadrupole Ion Trap Mag. Sector FTMS Electron Multiplier, Faraday cup PC’s UNIX Mac Basic components in mass spectrometer
  • 9. Mass Sor Illustration of the basic components of a mass spectrometry system. Solid • Liquid • Vapor Ionization Source Mass Analyzer Detector Inlet Form ions charged molecules selected ions Data System Sort or separates ions by M/Z When ions strike Detector it Detect ions The inlet transfers the sample into the vacuum of the mass spectrometer. In the source region, neutral sample molecules are ionized and then accelerated into the mass analyzer. The mass analyzer is the heart of the mass spectrometer. This section separates ions, either in space or in time, according to their mass to charge ratio. After the ions are separated, they are detected and the signal is transferred to a data system for analysis.. Neutral sample molecules 9VIGNAN PHARMACY COLLEGE
  • 11. VIGNAN PHARMACY COLLEGE 11 The mass spectrometer is an instrument which help in separating the individual atoms or molecules because of difference in their masses. Consider a molecule M, Which is bombarded with a beam of electrons M + e- M+. +2e- where, M+. is molecular ion or radical ion 2e- is electron Now voltage “v” is applied in an electric field then ions are accelerated. In this condition the energy given to each particle is zV and this is equal to kinetic energy which is equal to 1/2mv2 . THEORY
  • 12. i.e. potential energy=kinetic energy zV = 1/2mv2 2zV = mv2 2zV/m= v2 = v Where V = Velocity of particle m = mass z = charge of an electron V = Acceleration voltage All the particles posses some energy zV with some kinetic energy 1/2mv2, but m value changes from molecule to molecule with respect velocity ‘v’ also changes. i.e. ½ mv=zV VIGNAN PHARMACY COLLEGE 12
  • 13. When all charged particles have been accelerated by an applied voltage, they enter into a magnetic field “H”. Then attractive force is HzV. And balancing force of particle is mv2 /r. Centripetal = Centrifugal HzV=mv2/r Hz=mv/r From the above equation v= Hz=m / r By squaring on both sides H2 z2 = m2 (2zV/m) / r2 H2 z = 2v m/ r2 m/z = H2 r2 / 2v VIGNAN PHARMACY COLLEGE 13
  • 14. MASS SPECTRUM The mass spectrum is the plot of mass to charge ratio of positively charged ions against their relative abundance. The m/z ratio are taken along the abscissa, while relative abundance is taken on ordinate. BASE PEAK: The most intense peak in the mass spectrum is called the base peak. Base peak is the highest peak it is assigned a relative intensity of 100%. VIGNAN PHARMACY COLLEGE 14
  • 15. MOLECULAR ION PEAK: The ion formed from a molecule by removal of one electron of lowest ionization potential is known as molecular ion. The molecular ion is detected as mass to charge ratio that corresponds to molecular weight of molecule. The molecular ion peak gives the molecular weight of compound . The molecular ion peak is highest mass number except isotope peak. Molecular ion peakBase peak Fragment ions VIGNAN PHARMACY COLLEGE 15
  • 16. FRAGMENT IONS: The ions produced from the molecular ion by cleavage of bonds are called fragment ions They have lower masses and used as building blocks to reconstruct the molecular structure. Fragmentation of molecular ion cleavage bond occurs in heterolytic and homolytic cleavage. METASTABLE IONS: Mass spectrum of molecule shows sharp peaks at m/z integrals. But some show diffuse, broad low intensity peaks at non integral m/z values these are called metastable ions m1 + m2 ++ neutral fragment VIGNAN PHARMACY COLLEGE 16
  • 17. If in the reaction m1 +--------->m2 ++ takes place in source then the daughter ion may be m2 +. But m1 +----->m2 ++ if occurs after the source and before arrival at collector at lower mass than m2+ and is said to be metastable ion m*.The peak (m*) due to such fragmentation therefore occurs at lower mass than m2+ and generally broad. The relation between the m* with that of m1 + & m2+ can be written as m*=(mz+)/m1 VIGNAN PHARMACY COLLEGE 17
  • 18. Relativeabundance m/z values 110108 81 79 29 –C2 H5 M+2M+ CH3CH2Br VIGNAN PHARMACY COLLEGE 18
  • 19. Liquid chromatography–mass spectrometry (LC-MS, or alternatively HPLC-MS) is an ADVANCED ANALYTICAL INSTRUMNTAL technique that combines the physical separation capabilities of LIQUID CHROMATOGRAPHY (or HPLC) with the mass analysis capabilities of MASS SPECTROMETER VIGNAN PHARMACY COLLEGE 19
  • 20. It is the combination of liquid chromatography and the mass spectrometry. In LC-MS we are removing the detector from the column of LC and fitting the column to interface of MS. In the most of the cases the interface used in LC-MS are ionization source. 20VIGNAN PHARMACY COLLEGE
  • 21.  HPLC is a method for separating a complex mixture in to its individual components.  High sensitivity of mass spectrometry provides the information for identification of compounds or structural elucidation of compounds.  Combination of these two techniques is LC-MS VIGNAN PHARMACY COLLEGE 21
  • 22. VIGNAN PHARMACY COLLEGE 22 ION INTERFACE SOURCES DIRECT CHEMICAL IONIZATION MOVING WIRE OR BELT INTERFACE THERMOSPRAY
  • 23. DIRECT CHEMICAL IONIZATION: The simplest way to introduce HPLC effluent into mass spectrometer is to split the flow. Chemical ionization is most suitable in this technique because under CI pressure conditions, solvent rates as high as 10 micro lit / min can be tolerated. This permits10-20 micro lit/ min (1-2%) eluate from the HPLC to that of the ion source. VIGNAN PHARMACY COLLEGE 23
  • 25. MOVING WIRE OR BELT INTERFACE: The moving wire or belt interface consists of an auxiliary vacuum chamber through which a continuous train carries the column eluate, evaporates the solvent and subsequently vaporizes the solute. The moving interface was developed by Mc Fadden et al84,85 which can transfer upto 30-40% of solute from HPLC to ion source. The residual solvent helps to maintain vaccum in the MS. The sample is finally conducted into the ion source, where it vaporizes. VIGNAN PHARMACY COLLEGE 25
  • 27. THERMOSPRAY: The eluent from the column is vapourised and a portion of vapour is transferred to the mass spectrometer and rest of the vapour is pumped to waste. As a result a supersonic jet vapour, containing a mist of particles and solvent droplet is created. There vaporization takes place in presence of an electrolyte the LC buffer, the droplets are charged. And finally they enter into the ionization chamber. VIGNAN PHARMACY COLLEGE 27
  • 28. VIGNAN PHARMACY COLLEGE 28 Electron spray Ionization [ESI] Atmospheric pressure chemical ionization [APCI] Atmospheric Pressure photo ionization [APPI]
  • 29. The LC eluent is sprayed into chambers in presence of strong electrostatic field and heated drying gas. Large molecules even acquires more than one charge this process mathematically called deconvolution. The heated gas causes solvent in the droplet evaporation. The repulsive force b/w ions with like charge exceeds cohesive force and ions are eject into gas phase and passed into the analyser. VIGNAN PHARMACY COLLEGE 29
  • 31. In APCI, the LC eluent is sprayed through a heated [250-400] vapourises at atmospheric pressure. The heat vapourises liquid which results gas solvent are ionized by corona needle by which electrons are discharged. Thereby chemical reactions takes place and ions passes through a capillary orifice into mass analyser. VIGNAN PHARMACY COLLEGE 31
  • 32. Atmospheric pressure photo ionization is relatively never technique. Here a discharge UV lamp is placed which generates photons in a narrow range of ionization energies. It shows its ionization for highly non polar compounds and low flow rates[<100m/min] VIGNAN PHARMACY COLLEGE 32
  • 33. Mass analyzers Quadrupole Ion trap Time of flight Fourier transform ion cyclotron resonance VIGNAN PHARMACY COLLEGE 33 They deflects ions down a curved tubes in a magnetic fields based on their kinetic energy determined by the mass, charge and velocity. The magnetic field is scanned to measure different ions.
  • 34. VIGNAN PHARMACY COLLEGE 34 In a quadrupole mass analyser a set of four rods are arranged parallel to the direction. Here a DC current and radio frequency RF is applied to generate oscillating electrostatic field in between the rods. Based on this only m/z is been determined and stable oscillation takes place. And ion travels in quadrupole axis with cork screw type of trajectory.
  • 35. VIGNAN PHARMACY COLLEGE 35 TOF mass analyser is based on simple idea that the velocities of two ions are created by uniform electromagnetic force applied to all the ions at same time, causing them to accelerate down a flight tube. Lighter ions travels faster and strike the detector first so that the m/z ratio of ions is detected.
  • 37. The ion trap mass analyser operates by similar principles where it consists of circular ring electrode Plus two end caps that form a chamber. Here AC or DC power along RF potential is applied between the cups and the ring electrode. There the ions entering into the chamber are trapped by electromagnetic fields and they oscillates in concentric trajectories. This process is called resonant ejection. VIGNAN PHARMACY COLLEGE 37
  • 39. VIGNAN PHARMACY COLLEGE 39 In this ions entering are trapped in circular well defined orbits for extended periods by electrical and magnetic fields. These are excited by radio frequency RF and generates the current. This current is converted to Fourier transform into orbital frequencies. The angular frequency of motion is called cyclotron frequency.
  • 41. Photo graphic plates: It is used as it is capable of higher resolution and speeder than electronic devices. i.e. it can detect ions of all the masses and provide a reverse geometry analyzer. VIGNAN PHARMACY COLLEGE 41
  • 42. Faraday Cup: It is a metal cup into which all the ions are directed and the signal produced is very stable and reproducible. It is used on spectrometers where quantitative data is very important VIGNAN PHARMACY COLLEGE 42
  • 43. Electron multipliers: In this the current can be measured so accurately by just one ion strikes the detector can be measured i.e. when an ion strikes the surface of electron multiplier two electron are ejected. This process continues until the end of electro multiplier end is reached and electric current is analyzed and recorded with electron multiplier surface. Equation describe is 2n Where n= no of collisions with electron multiplier surface. VIGNAN PHARMACY COLLEGE 43
  • 44. DATA HANDLING All the mass spectrometers now employ computer control of same functions and also use a computerised display and output. The amount of data generated even by a fairly modest mass spectrometer is very large indeed, a single run may store data for upto 100 fragments from each type of molecule and if, LCMS analyses is being performed, a complete mass spectrum is generated and stored every sec for upto 90 min VIGNAN PHARMACY COLLEGE 44
  • 45. APPLICATIONS MOLECULAR WEIGHT DETERMINATION DIFFERENTIATION OF SIMILAR OCTAPEPTIDES: The spectra of octa peptides whose m/z ratio differ only by 1m/z. The only difference in sequence is at C-terminus that is one having threonine and other having threonine amide. VIGNAN PHARMACY COLLEGE 45
  • 46. DETERMINATION OF MOLECULAR WEIGHT OF GREEN FLORESCENT PROTEIN: GRF is 27000 Dalton protein with 238 amino acids. During electron spray ionization GFP acquires multiple charges. This allows to be analyzed by mass spectrometer by m/z range. Here the mass deconvolution is then used to determine the weight of the protein GFP. VIGNAN PHARMACY COLLEGE 46
  • 47. STRUCTURAL DETERMINATION: LC/MS is also applied for the information about the molecular structure. this can be in addition of mol wt if the identity of the compound is already known. STRUCUTRAL DETERMINATION OF GINSENOSIDES USING LC/MS ANALYSIS: GINSENG root have dozens of biologically active saponins called gensinosides. In mass spectrometer, ion trap mass analyser permits multiplier stages of precursor ion isolation and fragmentation The most prominent feature is sodium adduct ion corresponding to cleavage of single bonded glycoside. Subsequent isolation and fragmentation at m/z 789.7 yields two products. VIGNAN PHARMACY COLLEGE 47
  • 48. 1.A more abundant ion at m/z 365.1 losses oligosaccharide ion 2. Loss of less abundant ion at m/z 627.5 i.e. de-oxyhexose sugar VIGNAN PHARMACY COLLEGE 48
  • 49. PHARMACEUTICAL APPLICATIONS RAPID CHROMATOGRAPH OF BENZODIAZEPINES: It allows compounds to be separated even they are chromatographically unresolved. A series of benzodiazepines are analyzed using both UV and MS detectors. In this chlorine cl- has a characteristic abundance of 2 most abundant isotopes. By which TRAIZOLAM spectrum shows a two cl- ions and DIAZEPAM shows only one cl- ion. VIGNAN PHARMACY COLLEGE 49
  • 50. IDENTIFICATION OF BILE ACID METABOLITES: The use of in-vitro incubation of bile acid deoxycholic with rat liver microsomes to stimulate metabolism of drug candidate. These precursor ions are were automatically fragmented and full scan ion spectra is collected. The first graph shows the base peak chromatogram. The second shows minor metabolite which is eluted at 9.41min. Third graph show product spectrum from the ion at m/z 407 which confirms identity. VIGNAN PHARMACY COLLEGE 50
  • 52. CLINICAL APPLICATIONS HIGH SENSITIVITY DETECTION OF TRIMIPRAMINE AND THIORIDAZINE: Triminpramine is a tricyclic anti depressant, Thioridazine is a tranquilizer when these compounds are detected by UV there is no extract level. For this single quadrupole of LCMS was been used for analysis by ion monitoring. VIGNAN PHARMACY COLLEGE 52
  • 53. GENERAL CONSIDERATION: Immunoassays can be detected as it is more sensitive and very easily allocated. Similarly many drug and other small molecules assay are readily performed by immunoassay, LC/MS, GLC etc. Lc/ms is best suited for either problems i.e. those which have tedious specimen preparation protocols in which more than one compound must be measured simultaneously. BIOCHEMICAL GENETICS: One of the seminal applications of Lc/ms was multiple analyte screening for inborn errors of metabolism. Few of inherited metabolic disorders detected by newborn screening with Lc/ms. VIGNAN PHARMACY COLLEGE 53
  • 54.  AMINO ACIDOPATHIES Phenyl ketoxuria Tyrosinemia Non ketotic hyperglycemia Argininemia  ORGANIC ACIDEMIAS Glutaric academia type I Propionic academia Methyl malonic academia  DEFECTS OF FATTY ACID OXIDATION Short chain acyl-CoA dehydrogenase deficiency Ethylmalonic academia Carnitine transport defect VIGNAN PHARMACY COLLEGE 54
  • 55. THERAPEUTIC DRUG MONITORING: A direct injection of HPLC/MS method has been developed for the rapid identification and quantitation of seven tricyclic antidepressants in human plasma can be done. A sensitive and specific method is determined for phenprocoumon, warfarin in human plasma by Lc/ms has been developed for monitoring of anticoagulant therapy. VIGNAN PHARMACY COLLEGE 55
  • 56. FOOD APPLICATIONS INDENTIFICATION OF ALFATOXINS IN FOOD: Aflatoxins are fungi produced in food. By total in chromatogram we can detect 4 different aflatoxins. Even though they are structurally very similar to each other but can be uniquely identified by LC/ms. VIGNAN PHARMACY COLLEGE 56
  • 58. PHARMACOLOGY: Since most drugs have a core chemical structure, which is retained by their metabolites, the determination of drug metabolites in pharmacology is now dominated by Lc/ms. The core structure produces charged or neutral fragment. The charged can be detected using ion scanning strategy. Unchanged can be recognized by neutral loss scanning. VIGNAN PHARMACY COLLEGE 58
  • 59. TOXICOLOGY •An even simpler strategy solid phase extraction and direct flow injection with no HPLC has been shown to be viable using clinical specimens. • Determination of designer drugs 3,4-methylene dioxymethamphetamine[MDMA], 3,4-methylenedioxyethyl amphetamine[MDEA] and 3,4-methylenedioxy amphetamine[MDA] by Lc/ms has been showing using fluorescent detection. •The method was found suitable for determination for whole blood, serum, vitreous humor and urine. VIGNAN PHARMACY COLLEGE 59
  • 60. IN DRUG DISCOVERY Drug discovery involves a number of phases, including target identification, lead identification, small molecule optimization and pre- clinical and clinical development. Target identification has been speeded up as result of genomics but the measurement of gene transcription through detection of RNA does not necessarily indicate proteins produced are, which are translated by glycosylation or phosphorycation. With advances in Lc/ms, identification of translated proteins is possible. VIGNAN PHARMACY COLLEGE 60
  • 61.  LC-MS has proved to be an extremely sensitive and specific technique for the analysis of pharmaceuticals.  It plays important role in the studies of drug metabolism, discovery of new drug candidates and the analysis, identification and characterisation of impurities and degradants in drug substances and products. VIGNAN PHARMACY COLLEGE 61
  • 62. VIGNAN PHARMACY COLLEGE 62 Pharmaceutical Analysis -A Text book for pharmacy students & chemical applications By- DAVID G. WATSON. Page no: 206-213. Instrumental analysis By- SKOOG, HOLLER,CROUCH. Page no- 607-631. Spectroscopy By- PAVIA, LAMPMAN,KRIZ, VYVYAM Page no- 401-417.
  • 63. Elementary Organic Spectroscopy principles & chemical applications. By- Y.R.SHARMA Page No- 280-289 Instrumental Methods Of Chemical Analysis. By- B.K SHARMA Page No- C286-C291 Instrumental Methods Of Chemical Analysis By- GURDEEP R.CHATWAL,SHAM K.ANAND Page No 2.272-2.286 VIGNAN PHARMACY COLLEGE 63
  • 64. VIGNAN PHARMACY COLLEGE 64 Organic Spectroscopy Principles & Applications. By- JAG MOHAN Page no 443-446 Vogel’s Text Book Of Quantitative Chemical Analysis. By- J.MENDHAN, R C DENNY, J.D. BARNES, M.THOMAS, B. SIVA SANKAR. Page no 720-741 AGILENT TECHNOLOGIES. Page no 6-30