INTRODUCTION
 An earthquake is the perceptible shaking of the surface of the Earth due to
underground movement along a fault plane or from volcanic activity
 The severity of the shaking can range from barely felt to violent enough to toss
people around
 An Earthquake is the result of Sudden release of energy in the Earth’s crust
creates seismic waves, which causes vibration of the ground and structures
resting on it
 Depending on the characteristics of these vibrations, the ground may develop
cracks, fissures and settlements.
 Shaking and ground rupture are the main effects, principally resulting in more or
less severe damage to buildings and other rigid structures.
3
INTRODUCTION
 The possible risk of loss of life adds a very serious dimension to
seismic design, putting a moral responsibility on structural engineers.
 Objective of Earthquake Resistant Design is to make such buildings
that can resist effect of ground motion and would not collapse during
the strong Earthquake.
 In recent times, many new systems have been developed, either to
reduce the earthquake forces acting on the structure or to absorb a
part of seismic energy.
 One of the most widely researched, implemented and accepted
seismic protection systems is base isolation.
4
Earthquake Protective Systems
Passive Protective
Systems
Hybrid Protective
Systems
Active Protective
Systems
Tuned Mass
Damper
Energy Dissipation
Base Isolation
Active Isolation
Semi-Active
Isolation
Semi-Active Mass
Damping
Active Mass
Damping
Active Bracing
Adaptive Control
5
Base Isolation is the most common System
EARTHQUAKE PROTECTIVE SYSTEMS
What is Base Isolation?
 It is a system that may be defined as a flexible
or sliding interface positioned between a
structure and its foundation, for the purpose of
decoupling the horizontal motions of the
ground from the horizontal motions of the
structure, thereby reducing earthquake
damage to the structure and its contents.
Base isolation system absorbs and deflects the
energy released from the earthquake before it is
transferred to the structure
6
BASE-ISOLATED BUILDING
 The term isolation refers to reduced interaction between structure and the
ground.
 Since the seismic isolation system is located under the structure, it is referred as
‘Base isolation’.
 Base isolation is a passive control system meaning thereby that it does not
require any external force or energy for its activation.
 The base isolators used in this system mitigate the effect of an earthquake by
decoupling the components of the buildings from direct contact with the ground
essentially isolating the structure from potentially dangerous ground motions.
 The base-isolation techniques prove to be very effective for the seismic
protection of new framed buildings as well as for the seismic retrofitting of
existing ones.
7
OBJECTIVES OF SEISMIC ISOLATION SYSTEM
 Minimizing interruption of use of facility (Immediate
Occupancy Performance Level)
 Reducing damaging deformations in structural and
non-structural component
 Reducing acceleration response to minimize contents
related damage
 preventing plastic deformation of structural elements
 Protection of Building Frame
 Protection of Non-structural Components & Contents
 Provide for an Operational facility after the
Earthquake
 Protection of Life - Safety of occupants
 Improvement for Safety of Building
8
Enhance performance of structures at all hazard levels by,
The concept of separating the structure from the ground to avoid earthquake
damage is quite simple to grasp. After all, in an earthquake the ground moves
and it is this ground movement which causes most of the damage to
structures. An airplane flying over an earthquake is not affected.
So, the principle is simple. Separate the structure from the ground. The
ground will move but the building will not move.
9
Rigid attachment of a building to its foundation
-strengthen to resist damage ?
Decouple the structure from its foundation
-flexibility to resist damage ?
How can the structure be separated
from the ground for earthquake loads
but still resist gravity?
Ideal separation would be good.
Perhaps an air gap, frictionless rollers, a well-
oiled sliding surface, sky hooks, magnetic
levitation have practical restraints.
An air gap would not provide vertical
support; a sky-hook needs to hang from
something; frictionless rollers, sliders or
magnetic levitation would allow the building
to move for blocks under a gust of wind.
10PRINCIPLE OF BASE ISOLATION
11
12
ANIMATION SHOWING BASE ISOLATION
13
FIXED BASE ISOLATED BASE
14
RESPONSE OF BASE ISOLATED BUILDINGS
VERSUS FIXED BASE RESPONSE
Drift on Isolation Interface
Reduced Superstructure Deformations and acceleration response for
Base Isolated Structure
15
Earthquake Resistant House Base Isolated House
'Earthquake-resistant' technology enables the
building to counteract the earthquake load by
making its strength and resilience great enough to
resist shakings. Although it can protect the
building safely, it is ac-companied by a risk that
the furniture inside could fall or drop.
Seismic Isolation system turns destructive seismic
shakings into slower and softer ones preventing
possible damage. This structure can evade the
tremors, taking them in stride and safeguarding the
building, human lives and property
CONSIDERATION FOR SEISMIC ISOLATION
The benefits of using seismic isolation for earthquake resistant design
are:
 Isolation leads to a simpler structure with much less complicated seismic analysis as
compared with conventional structures
 Isolated designs are less sensitive to uncertainties in ground motion
 Minor damage at the design level event means immediate reoccupation
 The performance of the isolators is highly predictable, so they are much more reliable
than conventional structural components
 Even in case of larger-than-expected seismic events, damage will concentrate in the
isolation system, where elements can be easily substituted to restore the complete
functionality of the structure
 Base Isolation minimizes the need for strengthening measures like adding shear walls,
frames, and bracing by reducing the earthquake forces imparted to the building.
 Base Isolated building are capable of resisting GSA blasts loads and their ability to move
reduces the overall impact of the blast force on the building.
17
CONCEPT
OF
BASE ISOLATION
18
19
Base isolation, as a strategy to protect
structure from earthquake, revolves
around a few basic elements of
understanding
1. Period-shifting of structure
2. Mode of vibration
3. Damping and cutting of load
transmission path
4. Minimum rigidity
CONCEPT OF BASE ISOLATION
Isolators have large deformation potential allowing for
large drift on the Isolation Interface
BASIC ELEMENTS OF SEISMIC ISOLATION
The three basic elements in seismic isolation systems are,
 A vertical-load carrying device that provides lateral flexibility
so that the period of vibration of the total system is lengthened
sufficiently to reduce the force response
 A damper or energy dissipater so that the relative deflections
across the flexible mounting can be limited to a practical
design level
 A means of providing rigidity under low (service) load
 Steel plates, vulcanized rubber, and a lead plug in the center of
the design create these functional contrasting directional
components.
20
PRINCIPLE OF BASE ISOLATION
 The fundamental principle of base isolation is to modify the
response of the building so that the ground can move below the
building without transmitting these motions into the building.
 A building that is perfectly rigid will have a zero period.
 When the ground moves the acceleration induced in the structure
will be equal to the ground acceleration and there will be zero
relative displacement between the structure and the ground.
 The structure and ground move by same amount.
 A building that is perfectly flexible will have an infinite period.
 For this type of structure, when the ground beneath the structure
moves there will be zero acceleration induced in the structure and
the relative displacement between the structure and ground will
be equal to the ground displacement
 So in flexible structures the structure will not move, the ground
will.
21
INSTALLATION
OF
SEISMIC
ISOLATION
22
Layout and installation details for the isolation system
- depends on the site constraints, Type of structure, Construction and other related factors.
SEISMIC-ISOLATION CONFIGURATIONS
ISOLATOR LOCATIONS
 The requirement for installation of a base isolation system
is that the building be able to move horizontally relative to
the ground, usually at least 100 mm.
 The most common configuration is to install a diaphragm
immediately above the isolators.
 If the building has a basement then the options are to
install the isolators at the top, bottom or mid-height of the
basements columns and walls.
23
SUITABILITY OF BASE ISOLATION
 The subsoil does not produce a predominance of
long period ground motion.
 The structure is fairly jointed with sufficiently high
column load.
 The site permits horizontal displacements at the
base of the order of 200 mm or more.
 Lateral loads due to wind are less than
approximately 10% of the weight of the structure.
 The structure has two stories or more(heavy)
 The structure is fairly squat.
24
MOST EFFECTIVE
Structure on Stiff Soil
Structure with Low
Fundamental Period
(Low-Rise Building)
LEAST EFFECTIVE
Structure on Soft Soil
Structure with High
Fundamental Period
(High-Rise Building)
Each project must be assessed individually and early in design phase to determine
the suitability for seismic isolation.
IS IT AN ECONOMIC SOLUTION?
 Base isolation allows for a reduction in structural elements of the building with less ductile
detailing needed
 Widely held misconception is that seismic isolation is expensive
 E.g. Union House built in Auckland in 1983 with base isolation produced an estimated 7%
cost saving in the total construction cost of $6.6million which included a construction time
saving of 3 months due to the structural form requiring less seismic force, ductility
demands and structural deformations
 As a general rule the inclusion of all aspects of seismic isolation in a new structure will add
no more than 3% to total construction cost and considerably less when assessed against the
benefits of isolation
 Seismic isolation devices require no maintenance during the life of the building
 Following any significant event they should be inspected to ensure bolts and load plates are
still in place.
 Devices do not need replacing after an earthquake unless the event was in excess of their
design specification in which case removal of some devices for testing is recommended.
 Because the building is protected from major damage, repair costs following an earthquake
will be lower to non-existent
25
SLIDING SYSTEM
1. Resilient friction system
2. Friction pendulum system
ELASTOMERIC BEARING
1. Natural rubber bearing
2. Low damping rubber bearings
3. Lead plug bearings
4. High damping rubber bearing
26
TYPES OF BASE ISOLATION SYSTEMS
SLIDING SYSTEM
 Uses sliding elements between the foundation and base of the
structure.
 The sliding displacements are controlled by high-tension springs or
laminated rubber bearings, or by making the sliding surface curved.
 These mechanisms provide a restoring force to return the structure to
its equilibrium position.
27
TYPES OF BASE ISOLATION SYSTEMS
SLIDING ISOLATOR WITHOUT RECENTERING CAPACITY
 This consists of a horizontal sliding surface, allowing a displacement
and thus dissipating energy by means of defined friction between both
sliding components and stainless steel.
 One particular problem with a sliding structure is the residual
displacements that occur after major earthquakes.
28
TYPES OF BASE ISOLATION SYSTEMS
SLIDING ISOLATOR WITH RECENTERING CAPACITY
 Consists of a concave sliding plate.
 Due to geometry, each horizontal displacement results in a vertical
movement of the isolator.
 They remain horizontally flexible, dissipate energy and recenter the
superstructure into neutral position
29
TYPES OF BASE ISOLATION SYSTEMS
30
Flat Sliding Bearing
TYPES OF BASE ISOLATION SYSTEMS
FRICTION PENDULUM SYSTEM
 The Friction pendulum system (FPS) is a sliding isolation system
wherein the weight of the structure is supported on spherical sliding
surfaces that slide relative to each other when the ground motion exceeds
a threshold level.
31
TYPES OF BASE ISOLATION SYSTEMS
ELASTOMERIC ISOLATORS
 These are formed of thin horizontal layers of natural or synthetic rubber
bonded between steel plates.
 The steel plates prevent the rubber layers from bulging and so the
bearing is able to support higher vertical loads with only small
deformations.
 Plain elastomeric bearings provide flexibility but no significant damping
and will move under service loads.
32
TYPES OF BASE ISOLATION SYSTEMS
33
ELASTOMERIC ISOLATORS
LOW DAMPING NATURAL OR SYNTHETIC RUBBER BEARINGS
 Elastomeric bearings use either natural rubber or synthetic rubber (such
as neoprene), which have little inherent damping.
 For isolation they are generally used with special elastomer compounds
(high damping rubber bearings) or in combination with other devices
(lead rubber bearings).
34
TYPES OF BASE ISOLATION SYSTEMS
LEAD RUBBER BEARINGS
 A lead-rubber bearing is formed of a lead plug force-fitted into a pre-
formed hole in an elastomeric bearing.
 The lead core provides rigidity under service loads and energy dissipation
under high lateral loads.
 The entire bearing is encased in cover rubber to provide environmental
protection.
35
TYPES OF BASE ISOLATION SYSTEMS
 When subjected to low lateral loads (such as minor earthquake) the
lead rubber bearing is stiff both laterally and vertically.
36
TYPES OF BASE ISOLATION SYSTEMS
Seismic isolation is a relatively recent and evolving technology. It has been in increased
use since the 1980s, and has been well evaluated and reviewed internationally.
1st application in New Zealand in 1974
1st US application in 1984
1st Japanese application in 1985
1st Indian application in 2001
Traditionally, the application of the system is seen in larger buildings and bridges.
Additionally, engineers have made an effort to apply the system at a lower cost in
residential areas.
Base isolation techniques have been utilized worldwide for retrofitting historical
structures and monuments to reduce any possible destruction. Also on a smaller scale,
museums have started to use the system to ensure the security of artifacts
 Base Isolators need not be placed only at foundation level to resist earthquake ground
motions. They can even be placed at any floor level to isolate vibrations of machine also
37
Coal is burnt in the furnace of the steam generator and converts water to steam.
Steam will be conveyed to the turbine blades which will rotate the turbine. Turbine
is coupled to the generator and electricity is generated.
38
TURBO GENERATOR SUPPORTS
The resulting vibrations can be significant and therefore, the generator
must be isolated in such a way that the vibration is damped and not
transmitted to the foundation
This is accomplished by mechanical dampers or spring-mounting the
core
The turbo generator foundation is dynamically uncoupled from the
substructure
In order to protect the machine against earthquakes and to avoid
resonance amplitudes, the spring units are partially combined with
viscodamping,
39
40
Frame stiffness and natural frequencies of vibration are important
parameters due to the once per revolution (60/50 Hz) and twice per
revolution (120/100 Hz) characteristics of the generators in conjunction
with the stimulus from the power system frequency
Therefore great care is taken to ensure the natural frequencies of the
core and the frame are not near 60/50 or 120/100 Hz
BASE ISOLATION SYSTEM IN NEW BHUJ HOSPITAL
The 300 bed Bhuj Hospital that claimed 176
lives when it collapsed during the major
January 2001 Gujarat Earthquake is studied
 This was the first new building in India to be
fitted with earthquake – resistant NZ
developed base isolation technology
Structural engineers Dunning Thornton
Consultants from Wellington were part of the
New Zealand design team and supervised
installation of the first bearings on site in late
2001.
 280 lead rubber bearings were installed in
the structure
41
Armenia is the one of the world leaders in development and
application of base isolation technologies
The last applications of seismic isolation took place in design
and construction of 10-20-story multifunctional buildings
 The soil conditions in all cases are good and the soils here are
of category II with the predominant period of vibrations of not
more than 0.5 sec
42
 ‘Cascade’ building, as one of the most complicated building
43
 The first mode vibrations’ period in longitudinal
direction is equal to 1.90 sec and in transverse
direction - 1.91 sec, while the corresponding
periods for the non-isolated structure would be
0.83 sec and 0.86 sec
 This means that seismic isolation has reduced the
maximum spectral acceleration by a factor larger
than 2
 These figures prove the high effectiveness of
seismic isolation and reliability of the buildings
during strong seismic actions with the PGA equal
to 0.4 g and even more.
44
45
46
47
Seismic base isolation system has proved to be a reliable method of earthquake
resistant design.
The main significance of the system is to protect people and infrastructures from
the danger of seismic activity.
The success of this method is largely attributed to the development of isolation
devices and proper planning.
Noting that the advances in earthquake engineering and the construction practice
are as dynamic as the world we live in. In order to use the latest technology and
ensure highest level of safety in the built environment, it is imperative that the
design and construction communities utilize the most current technologies available
like the Base isolation system.
48

Weitere ähnliche Inhalte

Was ist angesagt?

Earthquake Resistant Designs
Earthquake Resistant DesignsEarthquake Resistant Designs
Earthquake Resistant DesignsJNTU
 
Earthquake Resistant Building
Earthquake Resistant Building  Earthquake Resistant Building
Earthquake Resistant Building akhil reddy
 
Earthquake resistant structure
Earthquake resistant structureEarthquake resistant structure
Earthquake resistant structurevikskyn
 
Simple Presentation Of BASE ISOLATION
Simple Presentation Of  BASE ISOLATION Simple Presentation Of  BASE ISOLATION
Simple Presentation Of BASE ISOLATION Mohamed Yassin
 
Prefabricated components
Prefabricated componentsPrefabricated components
Prefabricated componentsSofia Rajesh
 
Prestressed Concrete
Prestressed ConcretePrestressed Concrete
Prestressed ConcreteRavi Savani
 
Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]Sumit Srivastav
 
Earthquake and earthquake resistant design
Earthquake and earthquake resistant designEarthquake and earthquake resistant design
Earthquake and earthquake resistant designSatish Kambaliya
 
Earthquake Resistance planning
Earthquake Resistance planningEarthquake Resistance planning
Earthquake Resistance planningSumanta Das
 
Post-tensioning in Prestressed Concrete
Post-tensioning in Prestressed ConcretePost-tensioning in Prestressed Concrete
Post-tensioning in Prestressed ConcreteDavinderpal Singh
 
Earthquake resistance structures
Earthquake resistance structuresEarthquake resistance structures
Earthquake resistance structuresUday kumar Devalla
 
Earthquake resistant building construction
Earthquake resistant building constructionEarthquake resistant building construction
Earthquake resistant building constructiondaspriyabrata3
 
earthquake resistant design
earthquake resistant designearthquake resistant design
earthquake resistant designAditya Sanyal
 
Base isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh GhuraiyaBase isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh GhuraiyaMukesh Singh Ghuraiya
 

Was ist angesagt? (20)

Shear walls
Shear wallsShear walls
Shear walls
 
Earthquake Resistant Designs
Earthquake Resistant DesignsEarthquake Resistant Designs
Earthquake Resistant Designs
 
Earthquake Resistant Building
Earthquake Resistant Building  Earthquake Resistant Building
Earthquake Resistant Building
 
Shear wall ppt
Shear wall ppt Shear wall ppt
Shear wall ppt
 
Earthquake resistant structure
Earthquake resistant structureEarthquake resistant structure
Earthquake resistant structure
 
Simple Presentation Of BASE ISOLATION
Simple Presentation Of  BASE ISOLATION Simple Presentation Of  BASE ISOLATION
Simple Presentation Of BASE ISOLATION
 
Prefabricated components
Prefabricated componentsPrefabricated components
Prefabricated components
 
Prestressed Concrete
Prestressed ConcretePrestressed Concrete
Prestressed Concrete
 
Shear wall
Shear wallShear wall
Shear wall
 
Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]Base isolation.ppt [Autosaved] [Autosaved]
Base isolation.ppt [Autosaved] [Autosaved]
 
Retrofitting
RetrofittingRetrofitting
Retrofitting
 
Earthquake and earthquake resistant design
Earthquake and earthquake resistant designEarthquake and earthquake resistant design
Earthquake and earthquake resistant design
 
Earthquake Resistance planning
Earthquake Resistance planningEarthquake Resistance planning
Earthquake Resistance planning
 
Post-tensioning in Prestressed Concrete
Post-tensioning in Prestressed ConcretePost-tensioning in Prestressed Concrete
Post-tensioning in Prestressed Concrete
 
earthquake resistant ppt
earthquake resistant pptearthquake resistant ppt
earthquake resistant ppt
 
Design of staircases
Design of staircasesDesign of staircases
Design of staircases
 
Earthquake resistance structures
Earthquake resistance structuresEarthquake resistance structures
Earthquake resistance structures
 
Earthquake resistant building construction
Earthquake resistant building constructionEarthquake resistant building construction
Earthquake resistant building construction
 
earthquake resistant design
earthquake resistant designearthquake resistant design
earthquake resistant design
 
Base isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh GhuraiyaBase isolation and its Application By Mukesh Singh Ghuraiya
Base isolation and its Application By Mukesh Singh Ghuraiya
 

Andere mochten auch

Repair and Retrofit on Beam and Column Joints
Repair and Retrofit on Beam and Column JointsRepair and Retrofit on Beam and Column Joints
Repair and Retrofit on Beam and Column Jointsamerald24
 
Ray Optics Class 12 Part-1
Ray Optics Class 12 Part-1Ray Optics Class 12 Part-1
Ray Optics Class 12 Part-1Self-employed
 
Vibration measurement
Vibration measurementVibration measurement
Vibration measurementMark Nelson
 
How To Determine The Colour Of Transition Metal Complexes
How To Determine The Colour Of Transition Metal ComplexesHow To Determine The Colour Of Transition Metal Complexes
How To Determine The Colour Of Transition Metal ComplexesDenison Dwarkah
 
Geometrical optics
Geometrical opticsGeometrical optics
Geometrical opticsSiyavula
 
Charge transfer- color of the complexes
Charge transfer- color of the complexesCharge transfer- color of the complexes
Charge transfer- color of the complexesShobana Subramaniam
 
Geometric optics
Geometric opticsGeometric optics
Geometric opticsAnnie Amjad
 
Spectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexesSpectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexesChris Sonntag
 
Energy levels and absorption spectra
Energy levels and absorption spectraEnergy levels and absorption spectra
Energy levels and absorption spectraAlessio Bernardelli
 
Basics of Light, Refraction and Optics
Basics of Light, Refraction and OpticsBasics of Light, Refraction and Optics
Basics of Light, Refraction and OpticsKopp Glass, Inc.
 
Light & optics
Light & opticsLight & optics
Light & opticsitutor
 
Crystal field theory
Crystal field theoryCrystal field theory
Crystal field theorysurya287
 
Vibration Isolation and Base Excitation
Vibration Isolation and Base ExcitationVibration Isolation and Base Excitation
Vibration Isolation and Base ExcitationHimanshi Gupta
 
Transition metal complex
Transition metal complexTransition metal complex
Transition metal complexRawat DA Greatt
 
Spectrophotometry
SpectrophotometrySpectrophotometry
Spectrophotometrysuniu
 
Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...
Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...
Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...mariomS7
 

Andere mochten auch (19)

Repair and Retrofit on Beam and Column Joints
Repair and Retrofit on Beam and Column JointsRepair and Retrofit on Beam and Column Joints
Repair and Retrofit on Beam and Column Joints
 
Ray Optics Class 12 Part-1
Ray Optics Class 12 Part-1Ray Optics Class 12 Part-1
Ray Optics Class 12 Part-1
 
Vibration measurement
Vibration measurementVibration measurement
Vibration measurement
 
How To Determine The Colour Of Transition Metal Complexes
How To Determine The Colour Of Transition Metal ComplexesHow To Determine The Colour Of Transition Metal Complexes
How To Determine The Colour Of Transition Metal Complexes
 
Geometrical optics
Geometrical opticsGeometrical optics
Geometrical optics
 
Charge transfer- color of the complexes
Charge transfer- color of the complexesCharge transfer- color of the complexes
Charge transfer- color of the complexes
 
Geometric optics
Geometric opticsGeometric optics
Geometric optics
 
Spectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexesSpectroscopic methods uv vis transition metal complexes
Spectroscopic methods uv vis transition metal complexes
 
Energy levels and absorption spectra
Energy levels and absorption spectraEnergy levels and absorption spectra
Energy levels and absorption spectra
 
Basics of Light, Refraction and Optics
Basics of Light, Refraction and OpticsBasics of Light, Refraction and Optics
Basics of Light, Refraction and Optics
 
Light & optics
Light & opticsLight & optics
Light & optics
 
Crystal field theory
Crystal field theoryCrystal field theory
Crystal field theory
 
Vibration Isolation and Base Excitation
Vibration Isolation and Base ExcitationVibration Isolation and Base Excitation
Vibration Isolation and Base Excitation
 
Coordination chemistry
Coordination chemistryCoordination chemistry
Coordination chemistry
 
Transition metal complex
Transition metal complexTransition metal complex
Transition metal complex
 
coordination compounds
coordination compoundscoordination compounds
coordination compounds
 
Spectrophotometry
SpectrophotometrySpectrophotometry
Spectrophotometry
 
Mechanical Vibration- An introduction
Mechanical Vibration- An introductionMechanical Vibration- An introduction
Mechanical Vibration- An introduction
 
Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...
Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...
Ultra violet (UV) spectroscopy, introduction,principle instrumentation,differ...
 

Ähnlich wie Earthquake Base Isolation Explained

Base isolation topic as per jntu syllabus for m.tech 1st year structures
Base isolation topic as per jntu syllabus for m.tech 1st year structuresBase isolation topic as per jntu syllabus for m.tech 1st year structures
Base isolation topic as per jntu syllabus for m.tech 1st year structuresvaignan
 
Base isolation Engineering
Base isolation EngineeringBase isolation Engineering
Base isolation Engineeringshayoniguha
 
advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...nagham ali hasan
 
Base isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden houseBase isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden houseTwinkal Jambu
 
Microsoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATIONMicrosoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATIONSumit Srivastav
 
BASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptxBASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptxRahulKumar964014
 
Seismic retrofitting raj gajre
Seismic retrofitting raj gajreSeismic retrofitting raj gajre
Seismic retrofitting raj gajreRAJGajre1
 
BASE ISOLATION SYSTEM
BASE ISOLATION SYSTEMBASE ISOLATION SYSTEM
BASE ISOLATION SYSTEMSyed Jaber
 
vibration isolation
vibration isolationvibration isolation
vibration isolationpatilshiv407
 
Seismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitationsSeismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitationsKumarS250747
 
IRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated BuildingIRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated BuildingIRJET Journal
 
Seismic retrofitting of buildings
Seismic retrofitting of buildingsSeismic retrofitting of buildings
Seismic retrofitting of buildingsSukanta Paul
 
SEISMIC RETROFITTING OF BUILDINGS
SEISMIC RETROFITTING OF BUILDINGSSEISMIC RETROFITTING OF BUILDINGS
SEISMIC RETROFITTING OF BUILDINGSSukanta Paul
 
Base isolation method System for Multi storey Building
Base isolation method System for Multi storey BuildingBase isolation method System for Multi storey Building
Base isolation method System for Multi storey Buildingajinkyaraj
 
EARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTURESEARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTUREShemanthchintu135
 
Earthquake resistant structure By Engr. Ghulam Yasin Taunsvi
Earthquake resistant structure By Engr. Ghulam Yasin TaunsviEarthquake resistant structure By Engr. Ghulam Yasin Taunsvi
Earthquake resistant structure By Engr. Ghulam Yasin TaunsviShan Khan
 

Ähnlich wie Earthquake Base Isolation Explained (20)

Base isolation topic as per jntu syllabus for m.tech 1st year structures
Base isolation topic as per jntu syllabus for m.tech 1st year structuresBase isolation topic as per jntu syllabus for m.tech 1st year structures
Base isolation topic as per jntu syllabus for m.tech 1st year structures
 
Base isolation Engineering
Base isolation EngineeringBase isolation Engineering
Base isolation Engineering
 
advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...advanced construction technology - seismic isolation & passive-energy dissipa...
advanced construction technology - seismic isolation & passive-energy dissipa...
 
Earthquick rasistant structure
Earthquick rasistant structureEarthquick rasistant structure
Earthquick rasistant structure
 
Base isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden houseBase isolation earthquake resistance wooden house
Base isolation earthquake resistance wooden house
 
Microsoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATIONMicrosoft Word - BASE ISOLATION
Microsoft Word - BASE ISOLATION
 
BASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptxBASIC ISOLATION TECHNIQUE.pptx
BASIC ISOLATION TECHNIQUE.pptx
 
Seismic retrofitting raj gajre
Seismic retrofitting raj gajreSeismic retrofitting raj gajre
Seismic retrofitting raj gajre
 
BASE ISOLATION SYSTEM
BASE ISOLATION SYSTEMBASE ISOLATION SYSTEM
BASE ISOLATION SYSTEM
 
vibration isolation
vibration isolationvibration isolation
vibration isolation
 
Earthquake Fuse
Earthquake FuseEarthquake Fuse
Earthquake Fuse
 
Seismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitationsSeismic Retrofitting and repairs and rehabilitations
Seismic Retrofitting and repairs and rehabilitations
 
IRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated BuildingIRJET- Study of Base Isolated Building
IRJET- Study of Base Isolated Building
 
Seismic retrofitting of buildings
Seismic retrofitting of buildingsSeismic retrofitting of buildings
Seismic retrofitting of buildings
 
SEISMIC RETROFITTING OF BUILDINGS
SEISMIC RETROFITTING OF BUILDINGSSEISMIC RETROFITTING OF BUILDINGS
SEISMIC RETROFITTING OF BUILDINGS
 
Base isolation method System for Multi storey Building
Base isolation method System for Multi storey BuildingBase isolation method System for Multi storey Building
Base isolation method System for Multi storey Building
 
EARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTURESEARTHQUAKE RESISTANT STRUCTURES
EARTHQUAKE RESISTANT STRUCTURES
 
Earthquake resistant structure By Engr. Ghulam Yasin Taunsvi
Earthquake resistant structure By Engr. Ghulam Yasin TaunsviEarthquake resistant structure By Engr. Ghulam Yasin Taunsvi
Earthquake resistant structure By Engr. Ghulam Yasin Taunsvi
 
Earthquake
EarthquakeEarthquake
Earthquake
 
20620130101006
2062013010100620620130101006
20620130101006
 

Kürzlich hochgeladen

AntColonyOptimizationManetNetworkAODV.pptx
AntColonyOptimizationManetNetworkAODV.pptxAntColonyOptimizationManetNetworkAODV.pptx
AntColonyOptimizationManetNetworkAODV.pptxLina Kadam
 
22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...
22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...
22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...KrishnaveniKrishnara1
 
70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical training70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical trainingGladiatorsKasper
 
Input Output Management in Operating System
Input Output Management in Operating SystemInput Output Management in Operating System
Input Output Management in Operating SystemRashmi Bhat
 
Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...
Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...
Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...Sumanth A
 
March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...
March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...
March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...gerogepatton
 
SOFTWARE ESTIMATION COCOMO AND FP CALCULATION
SOFTWARE ESTIMATION COCOMO AND FP CALCULATIONSOFTWARE ESTIMATION COCOMO AND FP CALCULATION
SOFTWARE ESTIMATION COCOMO AND FP CALCULATIONSneha Padhiar
 
Mine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptxMine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptxRomil Mishra
 
Javier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptxJavier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptxJavier Fernández Muñoz
 
US Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of ActionUS Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of ActionMebane Rash
 
Theory of Machine Notes / Lecture Material .pdf
Theory of Machine Notes / Lecture Material .pdfTheory of Machine Notes / Lecture Material .pdf
Theory of Machine Notes / Lecture Material .pdfShreyas Pandit
 
Module-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdfModule-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdfManish Kumar
 
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.elesangwon
 
CME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTES
CME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTESCME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTES
CME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTESkarthi keyan
 
Virtual memory management in Operating System
Virtual memory management in Operating SystemVirtual memory management in Operating System
Virtual memory management in Operating SystemRashmi Bhat
 
"Exploring the Essential Functions and Design Considerations of Spillways in ...
"Exploring the Essential Functions and Design Considerations of Spillways in ..."Exploring the Essential Functions and Design Considerations of Spillways in ...
"Exploring the Essential Functions and Design Considerations of Spillways in ...Erbil Polytechnic University
 
Secure Key Crypto - Tech Paper JET Tech Labs
Secure Key Crypto - Tech Paper JET Tech LabsSecure Key Crypto - Tech Paper JET Tech Labs
Secure Key Crypto - Tech Paper JET Tech Labsamber724300
 
Computer Graphics Introduction, Open GL, Line and Circle drawing algorithm
Computer Graphics Introduction, Open GL, Line and Circle drawing algorithmComputer Graphics Introduction, Open GL, Line and Circle drawing algorithm
Computer Graphics Introduction, Open GL, Line and Circle drawing algorithmDeepika Walanjkar
 
STATE TRANSITION DIAGRAM in psoc subject
STATE TRANSITION DIAGRAM in psoc subjectSTATE TRANSITION DIAGRAM in psoc subject
STATE TRANSITION DIAGRAM in psoc subjectGayathriM270621
 
Immutable Image-Based Operating Systems - EW2024.pdf
Immutable Image-Based Operating Systems - EW2024.pdfImmutable Image-Based Operating Systems - EW2024.pdf
Immutable Image-Based Operating Systems - EW2024.pdfDrew Moseley
 

Kürzlich hochgeladen (20)

AntColonyOptimizationManetNetworkAODV.pptx
AntColonyOptimizationManetNetworkAODV.pptxAntColonyOptimizationManetNetworkAODV.pptx
AntColonyOptimizationManetNetworkAODV.pptx
 
22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...
22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...
22CYT12 & Chemistry for Computer Systems_Unit-II-Corrosion & its Control Meth...
 
70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical training70 POWER PLANT IAE V2500 technical training
70 POWER PLANT IAE V2500 technical training
 
Input Output Management in Operating System
Input Output Management in Operating SystemInput Output Management in Operating System
Input Output Management in Operating System
 
Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...
Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...
Robotics-Asimov's Laws, Mechanical Subsystems, Robot Kinematics, Robot Dynami...
 
March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...
March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...
March 2024 - Top 10 Read Articles in Artificial Intelligence and Applications...
 
SOFTWARE ESTIMATION COCOMO AND FP CALCULATION
SOFTWARE ESTIMATION COCOMO AND FP CALCULATIONSOFTWARE ESTIMATION COCOMO AND FP CALCULATION
SOFTWARE ESTIMATION COCOMO AND FP CALCULATION
 
Mine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptxMine Environment II Lab_MI10448MI__________.pptx
Mine Environment II Lab_MI10448MI__________.pptx
 
Javier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptxJavier_Fernandez_CARS_workshop_presentation.pptx
Javier_Fernandez_CARS_workshop_presentation.pptx
 
US Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of ActionUS Department of Education FAFSA Week of Action
US Department of Education FAFSA Week of Action
 
Theory of Machine Notes / Lecture Material .pdf
Theory of Machine Notes / Lecture Material .pdfTheory of Machine Notes / Lecture Material .pdf
Theory of Machine Notes / Lecture Material .pdf
 
Module-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdfModule-1-(Building Acoustics) Noise Control (Unit-3). pdf
Module-1-(Building Acoustics) Noise Control (Unit-3). pdf
 
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
2022 AWS DNA Hackathon 장애 대응 솔루션 jarvis.
 
CME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTES
CME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTESCME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTES
CME 397 - SURFACE ENGINEERING - UNIT 1 FULL NOTES
 
Virtual memory management in Operating System
Virtual memory management in Operating SystemVirtual memory management in Operating System
Virtual memory management in Operating System
 
"Exploring the Essential Functions and Design Considerations of Spillways in ...
"Exploring the Essential Functions and Design Considerations of Spillways in ..."Exploring the Essential Functions and Design Considerations of Spillways in ...
"Exploring the Essential Functions and Design Considerations of Spillways in ...
 
Secure Key Crypto - Tech Paper JET Tech Labs
Secure Key Crypto - Tech Paper JET Tech LabsSecure Key Crypto - Tech Paper JET Tech Labs
Secure Key Crypto - Tech Paper JET Tech Labs
 
Computer Graphics Introduction, Open GL, Line and Circle drawing algorithm
Computer Graphics Introduction, Open GL, Line and Circle drawing algorithmComputer Graphics Introduction, Open GL, Line and Circle drawing algorithm
Computer Graphics Introduction, Open GL, Line and Circle drawing algorithm
 
STATE TRANSITION DIAGRAM in psoc subject
STATE TRANSITION DIAGRAM in psoc subjectSTATE TRANSITION DIAGRAM in psoc subject
STATE TRANSITION DIAGRAM in psoc subject
 
Immutable Image-Based Operating Systems - EW2024.pdf
Immutable Image-Based Operating Systems - EW2024.pdfImmutable Image-Based Operating Systems - EW2024.pdf
Immutable Image-Based Operating Systems - EW2024.pdf
 

Earthquake Base Isolation Explained

  • 2.  INTRODUCTION TO EARTHQUAKE  CONCEPT OF BASE ISOLATION  TYPES OF BASE ISOLATION SYSTEMS  IMPLIMENTATION OF BASE ISOLATION  CASE STUDY  CONCLUSIONS 2CONTENTS
  • 3. INTRODUCTION  An earthquake is the perceptible shaking of the surface of the Earth due to underground movement along a fault plane or from volcanic activity  The severity of the shaking can range from barely felt to violent enough to toss people around  An Earthquake is the result of Sudden release of energy in the Earth’s crust creates seismic waves, which causes vibration of the ground and structures resting on it  Depending on the characteristics of these vibrations, the ground may develop cracks, fissures and settlements.  Shaking and ground rupture are the main effects, principally resulting in more or less severe damage to buildings and other rigid structures. 3
  • 4. INTRODUCTION  The possible risk of loss of life adds a very serious dimension to seismic design, putting a moral responsibility on structural engineers.  Objective of Earthquake Resistant Design is to make such buildings that can resist effect of ground motion and would not collapse during the strong Earthquake.  In recent times, many new systems have been developed, either to reduce the earthquake forces acting on the structure or to absorb a part of seismic energy.  One of the most widely researched, implemented and accepted seismic protection systems is base isolation. 4
  • 5. Earthquake Protective Systems Passive Protective Systems Hybrid Protective Systems Active Protective Systems Tuned Mass Damper Energy Dissipation Base Isolation Active Isolation Semi-Active Isolation Semi-Active Mass Damping Active Mass Damping Active Bracing Adaptive Control 5 Base Isolation is the most common System EARTHQUAKE PROTECTIVE SYSTEMS
  • 6. What is Base Isolation?  It is a system that may be defined as a flexible or sliding interface positioned between a structure and its foundation, for the purpose of decoupling the horizontal motions of the ground from the horizontal motions of the structure, thereby reducing earthquake damage to the structure and its contents. Base isolation system absorbs and deflects the energy released from the earthquake before it is transferred to the structure 6 BASE-ISOLATED BUILDING
  • 7.  The term isolation refers to reduced interaction between structure and the ground.  Since the seismic isolation system is located under the structure, it is referred as ‘Base isolation’.  Base isolation is a passive control system meaning thereby that it does not require any external force or energy for its activation.  The base isolators used in this system mitigate the effect of an earthquake by decoupling the components of the buildings from direct contact with the ground essentially isolating the structure from potentially dangerous ground motions.  The base-isolation techniques prove to be very effective for the seismic protection of new framed buildings as well as for the seismic retrofitting of existing ones. 7
  • 8. OBJECTIVES OF SEISMIC ISOLATION SYSTEM  Minimizing interruption of use of facility (Immediate Occupancy Performance Level)  Reducing damaging deformations in structural and non-structural component  Reducing acceleration response to minimize contents related damage  preventing plastic deformation of structural elements  Protection of Building Frame  Protection of Non-structural Components & Contents  Provide for an Operational facility after the Earthquake  Protection of Life - Safety of occupants  Improvement for Safety of Building 8 Enhance performance of structures at all hazard levels by,
  • 9. The concept of separating the structure from the ground to avoid earthquake damage is quite simple to grasp. After all, in an earthquake the ground moves and it is this ground movement which causes most of the damage to structures. An airplane flying over an earthquake is not affected. So, the principle is simple. Separate the structure from the ground. The ground will move but the building will not move. 9 Rigid attachment of a building to its foundation -strengthen to resist damage ? Decouple the structure from its foundation -flexibility to resist damage ?
  • 10. How can the structure be separated from the ground for earthquake loads but still resist gravity? Ideal separation would be good. Perhaps an air gap, frictionless rollers, a well- oiled sliding surface, sky hooks, magnetic levitation have practical restraints. An air gap would not provide vertical support; a sky-hook needs to hang from something; frictionless rollers, sliders or magnetic levitation would allow the building to move for blocks under a gust of wind. 10PRINCIPLE OF BASE ISOLATION
  • 11. 11
  • 12. 12
  • 13. ANIMATION SHOWING BASE ISOLATION 13 FIXED BASE ISOLATED BASE
  • 14. 14
  • 15. RESPONSE OF BASE ISOLATED BUILDINGS VERSUS FIXED BASE RESPONSE Drift on Isolation Interface Reduced Superstructure Deformations and acceleration response for Base Isolated Structure 15
  • 16. Earthquake Resistant House Base Isolated House 'Earthquake-resistant' technology enables the building to counteract the earthquake load by making its strength and resilience great enough to resist shakings. Although it can protect the building safely, it is ac-companied by a risk that the furniture inside could fall or drop. Seismic Isolation system turns destructive seismic shakings into slower and softer ones preventing possible damage. This structure can evade the tremors, taking them in stride and safeguarding the building, human lives and property
  • 17. CONSIDERATION FOR SEISMIC ISOLATION The benefits of using seismic isolation for earthquake resistant design are:  Isolation leads to a simpler structure with much less complicated seismic analysis as compared with conventional structures  Isolated designs are less sensitive to uncertainties in ground motion  Minor damage at the design level event means immediate reoccupation  The performance of the isolators is highly predictable, so they are much more reliable than conventional structural components  Even in case of larger-than-expected seismic events, damage will concentrate in the isolation system, where elements can be easily substituted to restore the complete functionality of the structure  Base Isolation minimizes the need for strengthening measures like adding shear walls, frames, and bracing by reducing the earthquake forces imparted to the building.  Base Isolated building are capable of resisting GSA blasts loads and their ability to move reduces the overall impact of the blast force on the building. 17
  • 19. 19 Base isolation, as a strategy to protect structure from earthquake, revolves around a few basic elements of understanding 1. Period-shifting of structure 2. Mode of vibration 3. Damping and cutting of load transmission path 4. Minimum rigidity CONCEPT OF BASE ISOLATION Isolators have large deformation potential allowing for large drift on the Isolation Interface
  • 20. BASIC ELEMENTS OF SEISMIC ISOLATION The three basic elements in seismic isolation systems are,  A vertical-load carrying device that provides lateral flexibility so that the period of vibration of the total system is lengthened sufficiently to reduce the force response  A damper or energy dissipater so that the relative deflections across the flexible mounting can be limited to a practical design level  A means of providing rigidity under low (service) load  Steel plates, vulcanized rubber, and a lead plug in the center of the design create these functional contrasting directional components. 20
  • 21. PRINCIPLE OF BASE ISOLATION  The fundamental principle of base isolation is to modify the response of the building so that the ground can move below the building without transmitting these motions into the building.  A building that is perfectly rigid will have a zero period.  When the ground moves the acceleration induced in the structure will be equal to the ground acceleration and there will be zero relative displacement between the structure and the ground.  The structure and ground move by same amount.  A building that is perfectly flexible will have an infinite period.  For this type of structure, when the ground beneath the structure moves there will be zero acceleration induced in the structure and the relative displacement between the structure and ground will be equal to the ground displacement  So in flexible structures the structure will not move, the ground will. 21
  • 22. INSTALLATION OF SEISMIC ISOLATION 22 Layout and installation details for the isolation system - depends on the site constraints, Type of structure, Construction and other related factors. SEISMIC-ISOLATION CONFIGURATIONS
  • 23. ISOLATOR LOCATIONS  The requirement for installation of a base isolation system is that the building be able to move horizontally relative to the ground, usually at least 100 mm.  The most common configuration is to install a diaphragm immediately above the isolators.  If the building has a basement then the options are to install the isolators at the top, bottom or mid-height of the basements columns and walls. 23
  • 24. SUITABILITY OF BASE ISOLATION  The subsoil does not produce a predominance of long period ground motion.  The structure is fairly jointed with sufficiently high column load.  The site permits horizontal displacements at the base of the order of 200 mm or more.  Lateral loads due to wind are less than approximately 10% of the weight of the structure.  The structure has two stories or more(heavy)  The structure is fairly squat. 24 MOST EFFECTIVE Structure on Stiff Soil Structure with Low Fundamental Period (Low-Rise Building) LEAST EFFECTIVE Structure on Soft Soil Structure with High Fundamental Period (High-Rise Building) Each project must be assessed individually and early in design phase to determine the suitability for seismic isolation.
  • 25. IS IT AN ECONOMIC SOLUTION?  Base isolation allows for a reduction in structural elements of the building with less ductile detailing needed  Widely held misconception is that seismic isolation is expensive  E.g. Union House built in Auckland in 1983 with base isolation produced an estimated 7% cost saving in the total construction cost of $6.6million which included a construction time saving of 3 months due to the structural form requiring less seismic force, ductility demands and structural deformations  As a general rule the inclusion of all aspects of seismic isolation in a new structure will add no more than 3% to total construction cost and considerably less when assessed against the benefits of isolation  Seismic isolation devices require no maintenance during the life of the building  Following any significant event they should be inspected to ensure bolts and load plates are still in place.  Devices do not need replacing after an earthquake unless the event was in excess of their design specification in which case removal of some devices for testing is recommended.  Because the building is protected from major damage, repair costs following an earthquake will be lower to non-existent 25
  • 26. SLIDING SYSTEM 1. Resilient friction system 2. Friction pendulum system ELASTOMERIC BEARING 1. Natural rubber bearing 2. Low damping rubber bearings 3. Lead plug bearings 4. High damping rubber bearing 26 TYPES OF BASE ISOLATION SYSTEMS
  • 27. SLIDING SYSTEM  Uses sliding elements between the foundation and base of the structure.  The sliding displacements are controlled by high-tension springs or laminated rubber bearings, or by making the sliding surface curved.  These mechanisms provide a restoring force to return the structure to its equilibrium position. 27 TYPES OF BASE ISOLATION SYSTEMS
  • 28. SLIDING ISOLATOR WITHOUT RECENTERING CAPACITY  This consists of a horizontal sliding surface, allowing a displacement and thus dissipating energy by means of defined friction between both sliding components and stainless steel.  One particular problem with a sliding structure is the residual displacements that occur after major earthquakes. 28 TYPES OF BASE ISOLATION SYSTEMS
  • 29. SLIDING ISOLATOR WITH RECENTERING CAPACITY  Consists of a concave sliding plate.  Due to geometry, each horizontal displacement results in a vertical movement of the isolator.  They remain horizontally flexible, dissipate energy and recenter the superstructure into neutral position 29 TYPES OF BASE ISOLATION SYSTEMS
  • 30. 30 Flat Sliding Bearing TYPES OF BASE ISOLATION SYSTEMS
  • 31. FRICTION PENDULUM SYSTEM  The Friction pendulum system (FPS) is a sliding isolation system wherein the weight of the structure is supported on spherical sliding surfaces that slide relative to each other when the ground motion exceeds a threshold level. 31 TYPES OF BASE ISOLATION SYSTEMS
  • 32. ELASTOMERIC ISOLATORS  These are formed of thin horizontal layers of natural or synthetic rubber bonded between steel plates.  The steel plates prevent the rubber layers from bulging and so the bearing is able to support higher vertical loads with only small deformations.  Plain elastomeric bearings provide flexibility but no significant damping and will move under service loads. 32 TYPES OF BASE ISOLATION SYSTEMS
  • 34. LOW DAMPING NATURAL OR SYNTHETIC RUBBER BEARINGS  Elastomeric bearings use either natural rubber or synthetic rubber (such as neoprene), which have little inherent damping.  For isolation they are generally used with special elastomer compounds (high damping rubber bearings) or in combination with other devices (lead rubber bearings). 34 TYPES OF BASE ISOLATION SYSTEMS
  • 35. LEAD RUBBER BEARINGS  A lead-rubber bearing is formed of a lead plug force-fitted into a pre- formed hole in an elastomeric bearing.  The lead core provides rigidity under service loads and energy dissipation under high lateral loads.  The entire bearing is encased in cover rubber to provide environmental protection. 35 TYPES OF BASE ISOLATION SYSTEMS
  • 36.  When subjected to low lateral loads (such as minor earthquake) the lead rubber bearing is stiff both laterally and vertically. 36 TYPES OF BASE ISOLATION SYSTEMS
  • 37. Seismic isolation is a relatively recent and evolving technology. It has been in increased use since the 1980s, and has been well evaluated and reviewed internationally. 1st application in New Zealand in 1974 1st US application in 1984 1st Japanese application in 1985 1st Indian application in 2001 Traditionally, the application of the system is seen in larger buildings and bridges. Additionally, engineers have made an effort to apply the system at a lower cost in residential areas. Base isolation techniques have been utilized worldwide for retrofitting historical structures and monuments to reduce any possible destruction. Also on a smaller scale, museums have started to use the system to ensure the security of artifacts  Base Isolators need not be placed only at foundation level to resist earthquake ground motions. They can even be placed at any floor level to isolate vibrations of machine also 37
  • 38. Coal is burnt in the furnace of the steam generator and converts water to steam. Steam will be conveyed to the turbine blades which will rotate the turbine. Turbine is coupled to the generator and electricity is generated. 38 TURBO GENERATOR SUPPORTS
  • 39. The resulting vibrations can be significant and therefore, the generator must be isolated in such a way that the vibration is damped and not transmitted to the foundation This is accomplished by mechanical dampers or spring-mounting the core The turbo generator foundation is dynamically uncoupled from the substructure In order to protect the machine against earthquakes and to avoid resonance amplitudes, the spring units are partially combined with viscodamping, 39
  • 40. 40 Frame stiffness and natural frequencies of vibration are important parameters due to the once per revolution (60/50 Hz) and twice per revolution (120/100 Hz) characteristics of the generators in conjunction with the stimulus from the power system frequency Therefore great care is taken to ensure the natural frequencies of the core and the frame are not near 60/50 or 120/100 Hz
  • 41. BASE ISOLATION SYSTEM IN NEW BHUJ HOSPITAL The 300 bed Bhuj Hospital that claimed 176 lives when it collapsed during the major January 2001 Gujarat Earthquake is studied  This was the first new building in India to be fitted with earthquake – resistant NZ developed base isolation technology Structural engineers Dunning Thornton Consultants from Wellington were part of the New Zealand design team and supervised installation of the first bearings on site in late 2001.  280 lead rubber bearings were installed in the structure 41
  • 42. Armenia is the one of the world leaders in development and application of base isolation technologies The last applications of seismic isolation took place in design and construction of 10-20-story multifunctional buildings  The soil conditions in all cases are good and the soils here are of category II with the predominant period of vibrations of not more than 0.5 sec 42
  • 43.  ‘Cascade’ building, as one of the most complicated building 43
  • 44.  The first mode vibrations’ period in longitudinal direction is equal to 1.90 sec and in transverse direction - 1.91 sec, while the corresponding periods for the non-isolated structure would be 0.83 sec and 0.86 sec  This means that seismic isolation has reduced the maximum spectral acceleration by a factor larger than 2  These figures prove the high effectiveness of seismic isolation and reliability of the buildings during strong seismic actions with the PGA equal to 0.4 g and even more. 44
  • 45. 45
  • 46. 46
  • 47. 47 Seismic base isolation system has proved to be a reliable method of earthquake resistant design. The main significance of the system is to protect people and infrastructures from the danger of seismic activity. The success of this method is largely attributed to the development of isolation devices and proper planning. Noting that the advances in earthquake engineering and the construction practice are as dynamic as the world we live in. In order to use the latest technology and ensure highest level of safety in the built environment, it is imperative that the design and construction communities utilize the most current technologies available like the Base isolation system.