2. Requirements
Note:
• We will require OMT R41H for
configuration of 2G part of 6201.
• BTS sw will be GSM-
BTS_SW_G11A_R29E_(OMT_FORMAT)
• BSC sw will be GSM-
BTS_SW_G11A_R29E_(BSC-FORMAT)
5. Go to create IDB then select the cabinet type as 6201 RUG, power system as -48 V
Dc & cabinet system as Extended because in combo there are 4 no of Fans.
10. Now in configuration wizard define RU position. In this window we can define
DUG,RUG,PDU shelf & slot position. In the beginning it will b shows as undefined
11. For 2G all RUs (DUG & RUG) shelves are define as C1/E1and corresponding slots
are define as above i.e.(1,3,5,7,9,11,13) For the PDU s shelves are define as F1,D1,B1
& respective slots will be 1.
19. Define power as default , as below . Then click ok and install IDB.
20. After click on install IDB if wrong RBS operational sate is shown then u should
change RBS state in local mode softly (go to cabinet –right click on DUG-change
maintenance state) then u observe a blue LED IS FLASING in DUG i.e. it is in local
mode.
21. As describe in previous slide . Then click on the install IDB icon
and go for the process . After complete IDB installation
change DUG maintenance state in REMOTE & physically the
BLUE LED is OFF. Then go to Define Present RUS make PDU2
as not present .